CEB-20FD64 CUI Inc, CEB-20FD64 Datasheet - Page 2

BUZZER PIEZO ELEMENT 6.4KHZ 20MM

CEB-20FD64

Manufacturer Part Number
CEB-20FD64
Description
BUZZER PIEZO ELEMENT 6.4KHZ 20MM
Manufacturer
CUI Inc
Series
CEBr
Type
Feed Backr
Datasheet

Specifications of CEB-20FD64

Frequency
6.4kHz
Impedance
400 Ohm
Voltage - Input, Max
30V p-p
Capacitance @ Frequency
10000pF @ 1kHz
Size
0.79" Dia (20mm)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
102-1129
CEB20FD64
SEB-20FD64
SEB20FD64
Measuring Methods
1) Resonant frequency / Resonant impedance
2) Static capacitance
Mechanical Characteristics
Item
Solderability
Lead Wire Pull Strength
Vibration
The piezo electric diaphragm should be clamped at a node point (as shown in the following figure) to be free from any
mechanical stress. Measure its resonant frequency and resonant impedance by using a vector impedance analyzer or
equivalent.
When the input frequency is swept within 100 Hz to 9 KHz, the resonant frequency is defined as the frequency where
the impedance shows minimum value. This impedance should be the resonant impedance.
The electrostatic capacitance should be measured at 1 KHz by using an L.C.R. meter (ex. HP4194A(H.P.)) or
equivalent. The part should be clamped in the same way as the measurement or resonant frequency / resonant
impedance mentioned above.
Phone: 800.275.4899
Fax: 503.612.2381
Test Condition
Stripped wires of lead wires are immersed in
rosin for 5 seconds and then immersed in
solder bath of 270 ±5°C for 3 ±0.5 seconds.
The horizontal force of 3.0N (0.306kg) should
be applied to the double lead wire for 30 sec.
The diaphragm should be measured after
applying a vibration amplitude of 1.5 mm with
10 to 55 Hz band of vibration frequency to each
of the 3 perpendicular directions for 2 hours.
Part No: CEB-20FD64
Description: piezo electric diaphragm
www.cui.com
20050 SW 112th Ave.
Evaluation Standard
90% min. of the stripped wires
will be wet with solder.
(Except the edge of the terminal)
No damage or cutting off.
The value of the resonant
frequency should be ±10% of the
initial measurements.
Electrostatic capacitance should
be ±20% compared with the initial
measurement. The resonant
impedance should be 2000Ω
max.
Tualatin, OR 97062
Date: 6/25/2007
Unit: mm
Page No: 2 of 4