PFP-100N2 Omron, PFP-100N2 Datasheet - Page 3

TRACK DIN RAIL 1M HIGH PRO

PFP-100N2

Manufacturer Part Number
PFP-100N2
Description
TRACK DIN RAIL 1M HIGH PRO
Manufacturer
Omron
Series
PFPr
Datasheets

Specifications of PFP-100N2

Size
1.378" W x 0.630" H (35.00mm x 16.00mm)
Length
39.370" (1000.00mm)
Slotted/unslotted
Slotted
Thickness
0.059" (1.50mm)
Termination Style
Screw
Accessory Type
DIN Rail
Associated Relay Series
S8VM
Mounting Style
DIN Rail
Width
29.2 mm
External Width
16mm
Connector Type
Relay Accessory
Rohs Compliant
Yes
For Use With
Z2251 - MOUNTING PLATE ONE TOUCH G3NA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
PFP-100N2
PFP100N2
Z2611
Specifications Table
Note: Ratings and characteristics are defined at the power supply output terminals.
Engineering Data

S8E1
Note: The derating curve depends on the mounting position
Open-frame type
Covered-type
Characteristics
Ambient temperature
Ambient temperature
Ambient humidity
Ambient humidity
Dielectric strength
Insulation resistance
Vibration resistance
Shock resistance
Output indicator
Electromagnetic interference
Approved standards
Life expectancy
Weight (covered-type)
DERATING CURVE
DC inputs are not included in safety standard approvals.
of the power supply. The left curve is obtained from a
model mounted in one of the standard positions.
Ambient temperature (  C)
Ambient temperature (  C)
Natural air-cooling
Natural air-cooling
-- continued from previous page
Forced-air cooling
Forced-air
cooling
Operating
Storage
Operating
Storage
See the derating curve in the Engineering Data section.
25% to 85%
20% to 90%
2,000 VAC, 50/60 Hz for 1 min. (between all inputs and outputs/GR terminal)
100 M min. at 500 VDC (between all outputs and inputs/GR terminal)
Malfunction: 10 to 55 Hz, 0.75-mm double amplitude (44.1 m/s
2 h each in X, Y, and Z directions
Malfunction: 294 m/s
Green LED
Conforms to FCC class A standards and 1st group of VCCI
UL 1012, CSA E.B.1402
8 yrs. min. (40 C at the rated input with a 50% load)
200 g max.
--20 C to 65 C (--4 F to 149 F)
Mounting Position
Standard (Vertical) Installation

Models with a power rating of 10 or 15 W incorporate a Zener
diode clamp circuit. If the protection circuit is triggered, contact
your OMRON representative for repairs.
Models with a power rating of 25 or 50 W incorporate a shut-off
circuit. If the protection circuit is triggered, turn off the input power
and leave the power supply off for at least one minute before
turning it on again.
2
240 g max.
(approx. 30G), 3 times each in X, Y, and Z directions
OVERVOLTAGE PROTECTION
(5-V OUTPUT MODELS ONLY)
320 g max.
Horizontal Installation
2
, approx. 4.5G) for
440 g max.
S8E1