K32 -L49MB Omron, K32 -L49MB Datasheet - Page 5

no-image

K32 -L49MB

Manufacturer Part Number
K32 -L49MB
Description
MOUNTING BRACKET FOR K3TE
Manufacturer
Omron
Datasheet

Specifications of K32 -L49MB

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K32-L49MB
K32L49MB
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Application Examples
Input
High DC Voltage Measurement
When voltage exceeding the maximum voltage in the
standard range is measured (for example: more than
200 V), a divider is connected externally.
Lo
E
http://www.ia.omron.com/
1
Divider
R
R
1
2
E
Hi
Lo
2
92
96
E
E
2
1
Digital
panel
meter
=
R
1
R
+ R
48
2
2
3.5
70
Input
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Large DC Current Measurement
When large DC current exceeding 2 A is measured, a
shunt is connected externally.
43
Hi
Lo
45
Current
+0.6
−0
Note: The values above are recommended
values. Do not group-mount the meters
at intervals less than the
recommended ones.
Shunt
Panel Cutouts
LED Indicator Size
7.8 mm
120 min.
Voltage
(mV)
When current range DPM is
used, disconnect the internal
shunt resistor.
Hi
Lo
14.2 mm
92
+0.8
−0
Digital
panel
meter
75 min.
K3TE
5