H7EC-NV Omron, H7EC-NV Datasheet - Page 10

COUNT TOTALIZER DC IN 30HZ/1KHZ

H7EC-NV

Manufacturer Part Number
H7EC-NV
Description
COUNT TOTALIZER DC IN 30HZ/1KHZ
Manufacturer
Omron
Series
H7ECr
Datasheets

Specifications of H7EC-NV

Count Rate
30Hz or 1kHz Selectable
Number Of Digits/alpha
8
Input Type
Transistor
Voltage - Supply
None Required (Battery Included)
Display Type
LCD Non-Backlit
No. Of Digits / Alpha
8
Digit Height
8.6mm
Power Consumption
300mW
Operating Temperature Range
-10°C To +55°C
Svhc
No SVHC (15-Dec-2010)
Count Speed Max
1kHz
External Depth
48.5mm
Display Scan Rate Max
1kHz
Display Scan Rate Min
30Hz
Equipment Type
Self-Powered Count Totalizer
Dimensions
48 mm L x 24 mm W x 48.5 mm H
Mounting Style
Panel
Primary Voltage Rating
4.5 VDC to 30 VDC
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
H7EC-NV
H7ECNV
Z3008

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H7EC-NV
Manufacturer:
OMRON
Quantity:
100
Part Number:
H7EC-NV
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Part Number:
H7EC-NV-BH
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
H7EC
J RESET INPUT AND COUNT INPUT
The H7EC operates using its built-in Battery. If the H7EC is
connected to a device that has +V and OUT terminals that are
connected with a diode as shown in the circuit diagram, the
circuit indicated by the arrow 1 or 2 will be formed when the
device is turned OFF. As a result, the H7EC may be reset or
count by one. It is recommended that such devices not be
connected to the H7EC.
If an excessive voltage is applied to the count or reset input
terminals, the internal elements may be damaged.
Ensure that the following voltages are not exceeded:
SPNP/NPN universal voltage input model: 30 VDC
SAC/DC voltage input model:
Do not remove the outer case when voltage is being applied to
the power supply terminals or to the input terminals.
The input for the H7Ej-NFV-j is a high-impedance circuit so
influence from an induced voltage may result in malfunction.
When the input signal wiring is longer than 10 m (stray
capacitance of 120 pF/m, at room temperature), a CR filter or a
bleeder resistor should be connected.
At count input:
At reset input:
No-voltage input model: 3 VDC
Count input
or reset input
240 VAC (peak voltage: 338V)
240 VDC
3 VDC (no-voltage input)
10
J COUNT INPUT OR RESET INPUT TO
PNP/NPN Universal DC Voltage Input
Note:
No-voltage Input
Note: 1. The leakage current of the transistor used for input
MORE THAN ONE H7E COUNTER AT
A TIME
2. The forward voltage of the diode must be as low as
H (Reset ON) level must be 4.5 V minimum.
H =
must be less than 1 µA.
possible (i.e., 0.1 V maximum with an I
the voltage between terminals 3 and 4 will be 0.5 V
when the reset input is ON.
4.7 (kΩ)/N + V
4.7 (kΩ)/N + R
or
or
F
of 20 µA) so
H7EC
or