H7EC-NV Omron, H7EC-NV Datasheet - Page 11

COUNT TOTALIZER DC IN 30HZ/1KHZ

H7EC-NV

Manufacturer Part Number
H7EC-NV
Description
COUNT TOTALIZER DC IN 30HZ/1KHZ
Manufacturer
Omron
Series
H7ECr
Datasheets

Specifications of H7EC-NV

Count Rate
30Hz or 1kHz Selectable
Number Of Digits/alpha
8
Input Type
Transistor
Voltage - Supply
None Required (Battery Included)
Display Type
LCD Non-Backlit
No. Of Digits / Alpha
8
Digit Height
8.6mm
Power Consumption
300mW
Operating Temperature Range
-10°C To +55°C
Svhc
No SVHC (15-Dec-2010)
Count Speed Max
1kHz
External Depth
48.5mm
Display Scan Rate Max
1kHz
Display Scan Rate Min
30Hz
Equipment Type
Self-Powered Count Totalizer
Dimensions
48 mm L x 24 mm W x 48.5 mm H
Mounting Style
Panel
Primary Voltage Rating
4.5 VDC to 30 VDC
Termination Style
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
H7EC-NV
H7ECNV
Z3008

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H7EC-NV
Manufacturer:
OMRON
Quantity:
100
Part Number:
H7EC-NV
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Part Number:
H7EC-NV-BH
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
■ Characteristics
Note: Weight includes waterproof packing and flush mounting bracket.
■ Reference Value
Time accuracy
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
EMC
Degree of protection
Weight (see note)
Battery life
Item
Item
10 years min. with continuous input at
25°C (lithium battery)
±100 ppm (25°C)
100 MΩ min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts, and between the backlight pow-
er supply and timer input terminals/re-
set terminals for backlight models
1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts and between the backlight power
supply and timer input terminals/reset
terminals for backlight models
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
Square-wave noise generated by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
±600 V (Between timer input terminals/
Between reset terminals)
±480 V (Between the backlight power
supply terminals for backlight models)
±8 kV (malfunction)
Malfunction: 0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Malfunction: 200 m/s
Destruction: 300 m/s
(EMI)
Emission Enclosure:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves:
Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst:
Front panel:
Terminal block: IP20
No-backlight model: Approx. 60 g
Backlight model: Approx. 65 g
H7ET-NV@-H@
H7ET-NV@-@
Value
IP66, NEMA4 with waterproof packing
2
2
3 times each in 6 directions
3 times each in 6 directions
EN61326
EN55011 Group 1 class B
EN61326
EN61000-4-2: 4 kV contact discharge (level 2)
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
EN61000-4-3: 10 V/m (900 MHz ± 5 MHz) (level 3)
EN61000-4-4: 2 kV power line (level 3)
The battery life is calculated according to the conditions in the left column and
therefore is not a guaranteed value. Use these value as reference for mainte-
nance or replacement.
100 MΩ min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts and between timer input termi-
nals and reset terminals
3,700 VAC, 50/60 Hz for 1 min between
timer input terminals and exposed non-
current-carrying metal parts
2,200 VAC, 50/60 Hz for 1 min between
reset terminals and exposed non-cur-
rent-carrying metal parts and between
timer input terminals and reset termi-
nals
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
3 kV between timer input terminals and
reset terminals
±1.5 kV (Between timer input termi-
nals)
±500 V (Between reset terminals)
Approx. 60 g
H7ET-NFV@-@
8 kV air discharge (level 3)
2 kV I/O signal line (level 4)
Note
100 MΩ min. (at 500 VDC) between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts
1,000 VAC, 50/60 Hz for 1 min between
current-carrying metal parts and ex-
posed non-current-carrying metal
parts
4.5 kV between current-carrying termi-
nal and exposed non-current-carrying
metal parts
±500 V (Between timer input terminals/
Between reset terminals)
Approx. 60 g
H7ET-N@-@
New H7ET
11