COUNTER DIGITAL 12VDC 2 STAGE

H7CX-AWD1-N DC12-24/AC24

Manufacturer Part Number
H7CX-AWD1-N DC12-24/AC24
Description
COUNTER DIGITAL 12VDC 2 STAGE
Manufacturer
Omron

Specifications of H7CX-AWD1-N DC12-24/AC24

Count Rate
30Hz or 5kHz Selectable
Number Of Digits/alpha
6
Input Type
Voltage, Switch Closure, Transistor Switch
Output Type
Switch Closure
Voltage - Supply
12 V ~ 24 VDC, 24VAC
Display Type
LCD Backlit
No. Of Digits / Alpha
6
Digit Height
10mm
Power Consumption
4.7W
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Character Size
9mm
Supply Voltage Min
12VDC
Panel Cutout Width
45mm
Meter Function
Counter
Rohs Compliant
Yes
Connector Type
Screw Terminal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-AWD1-N-DC12-24/AC24
H7CXAWD1NDC1224AC24
Z3047
H7CX-AD-N/-ASD-N/-AWSD-N/-A4D-N/-A4SD-N/-A4WSD-N (Flush Mounting Models)
H7CX-A11-N/-A11S-N/-A11D1-N/-A11SD1-N/-A114-N/-A114S-N/-A114D1-N (Flush Mounting/Surface Mounting Models)
Dimensions with Flush Mounting Adapter
H7CX-A-N/-AS-N/-AW-N/-AWS-N/-AWD1-N/-AWSD1-N/-A4-N/-A4S-N/-A4W-N
(Provided with Adapter and Waterproof Packing)
H7CX-AD-N/-ASD-N/-AWSD-N/-A4D-N/-A4SD-N/-A4WSD-N
(Provided with Adapter and Waterproof Packing)
H7CX-A11-N/-A11S-N/-A11D1-N/-A11SD1-N/-A114-N/-A114S-N/-A114D1-N
(Adapter and Waterproof Packing Ordered Separately)
58
58
58
Y92S-29 (order separately)
Waterproof Packing
48
48
48
Y92S-29 (provided)
Waterproof Packing
Y92S-29 (provided)
Waterproof Packing
(51)
(51)
(51)
7.5
7.5
7.5
48
48
48
48
Panel
Panel
Panel
57.5
Y92F-30 (provided)
Flush Mounting Adapter
6
6
Y92F-30 (provided)
Flush Mounting Adapter
Y92F-30 (order separately)
Flush Mounting Adapter
76.5
89.9
Note: M3.5 terminal screw (effective length: 6 mm)
59
63.7
44.8
14.4
44.8
44.8
44.8
Panel Cutouts
Panel cutouts are as shown below. (according
to DIN43700).
Note: 1. The mounting panel thickness
Dimensions with Front
Connecting Socket
* These dimensions depend on the kind of DIN Track.
(Reference value)
2. To allow easier operation, it is
3. It is possible to mount counters
60 min.
P2CF-11(-E) Front Connecting Socket
With Y92A-48F1 attached.
With Y92A-48 attached.
A={48n 2.5+(n 1) 4}
103.2*
A=(51n 5.5)
should be 1 to 5 mm.
recommended that Adapters be
mounted so that the gap between
sides with hooks is at least 15 mm
(i.e., with the panel cutouts
separated by at least 60 mm).
side by side, but only in the
direction without the hooks. If they
are mounted side-by-side, water-
resistance will be lost.
15 min.
45
+ 0.6
n Units mounted
0
A=(48n 2.5)
side by side
(order separately)
H7CX-A@-N
45
A
H7CX
-A11@
+ 0.6
+1
0
0
60 min.
+1
0
+1
0
100.9