H7GP-TB Omron, H7GP-TB Datasheet - Page 5

COUNTER TIME LCD 6DIGT 100-240V

H7GP-TB

Manufacturer Part Number
H7GP-TB
Description
COUNTER TIME LCD 6DIGT 100-240V
Manufacturer
Omron
Type
Time Totalizerr
Datasheets

Specifications of H7GP-TB

Operating Mode
Accumulative
Output Type
*
Voltage - Supply
*
Termination Style
Screw Terminal
Display Type
*
Input Type
*
Number Of Digits/alpha
*
Count Rate
*
Voltage Rating
100 V to 240 V
Mounting
Panel
Counting Method
Accumulative
Size
80 mm L x 44 mm W x 22 mm H
Features
NEMA 4 protection using Y92S-32 rubber gasket supplied with unit, NPN and PNP operations
Time Range
99999.9hr
Power Consumption
6.5VA
Reset Time
20ms
Character Size
8.5mm
Height
24mm
Mounting Type
Panel
Supply Voltage Min
100VAC
Color
Black
Connector Type
Screw Terminals
Width
48mm
Depth
80mm
No. Of Digits / Alpha
6
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
H7GPTB
Operation
■ DIP Switch Settings
Set all DIP switches before mounting the Counter to a control panel.
All switches are set toward the display panel before shipping.
H7GP-C/-CD
■ Operating Modes
Nomenclature
Note: The count value will return to "0" when "999999" is
Display
3 (On right side
from front)
4 (On left side
from front)
Total Counters
Count input
Reset input
999999
Switch
exceeded.
4
2
0
http://www.ia.omron.com/
Input mode (note
1)
Counting speed
(note 1)
Item
1
Display side
Terminal side
Display side
Terminal side
Function
30 Hz
NPN
PNP
5 kHz
3
Display
Time Counters
Reset input
Start input
Note: Display values are shown for full scale set to 99999.9 h.
99999.9 h
(see note)
H7GP-T/-TD
Note: 1. When the setting has been changed, turned power off and
3 (On right side
from front)
4 (On left side
from front)
0.0h
The count value will return to "0" when "99999.9" is
exceeded.
1. Reset Key
2. Key Protection Indicator
3. NPN/PNP DIP Switch
4. Counting Speed DIP Switch (H7GP-C)
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Switch
2. The decimal point will flash every second when “99999.9 h”
Resets the count value, but will not operate while
the keys are protected.
Lit while the keys are protected. (Reset Key is
disabled.).
(Count or start with reset)
When the setting has been changed, turned power
off and on to continue. The display will show "0"
when the power is turned back on. See below for
details.
Time Range DIP Switch (H7GP-T)
When the setting has been changed, turned power
off and on to continue. The display will show "0"
when the power is turned back on. Refer to DIP
Switch Setting for details.
on to continue. The display will show “0” when the power is
turned back on.
is set.
Input mode
(note 1)
Time range
(note 1)
Item
Display side
Terminal side
Display side
Terminal side
Function
NPN
PNP
99999.9h
(note 2)
99 h 59 min
59 s
H7GP
5