H7CX-A4W AC100-240 Omron, H7CX-A4W AC100-240 Datasheet - Page 25

COUNTER SCREW-TERM 4DIGIT SPDT

H7CX-A4W AC100-240

Manufacturer Part Number
H7CX-A4W AC100-240
Description
COUNTER SCREW-TERM 4DIGIT SPDT
Manufacturer
Omron
Series
H7CXr
Datasheet

Specifications of H7CX-A4W AC100-240

Count Rate
*
Number Of Digits/alpha
6
Input Type
*
Output Type
*
Voltage - Supply
100 V ~ 240 VAC
Display Type
*
No. Of Digits / Alpha
4
Meter Function
Counter
Signal Input Type
PNP/NPN
Supply Voltage Max
240VAC
Character Size
11.5mm
Ip/nema Rating
IP66 / NEMA 4
Panel Cutout Height
45mm
Supply Voltage Min
100VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H7CX-A4WAC100-240
H7CXA4WAC100240
Note: 1. The full scale (FS) for H7CX 4-digit models is 9999.
Output
setting
mode
2. When the present value reaches 999999, it returns to 0.
3. Counting cannot be performed during reset/reset 1 input.
4. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
5. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output
6. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.
will turn ON again for the duration of the output time setting once the power supply has recovered.
K-1
Q
A
P
999999
999999
999999
999999
Set
value 2
Set
value 1
OUT1
OUT2
Reset/
reset 1
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
Reset/
reset 1
Set
value 2
Set
value 1
OUT1
OUT2
Reset/
reset 1
Set
value 1
OUT1
OUT2
Set
value 2
0
0
0
0
UP
Input mode
DOWN
UP/DOWN A, B, C
The present value dis-
play continues to in-
crease/decrease.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time.The
OUT1 one-shot out-
put time is indepen-
dent of OUT2.
The present value dis-
play does not change
during the one-shot
output time period,
but the actual count
returns to the reset
start status.
The outputs return to
the one-shot start
state and repeat one-
shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time. The
OUT1 one-shot out-
put time is indepen-
dent of OUT2.
The present value
continues to increase/
decrease for the one-
shot output time, but
returns to the reset
start status after the
one-shot output time
has elapsed.
The outputs repeat
one-shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time. The
OUT1 one-shot out-
put time is indepen-
dent of OUT2.
The present value dis-
play and OUT1 self-
holding output is held
until reset/reset 1 is
input. OUT1 and
OUT2 are indepen-
dent.
count completion
Operation after
H7CX-A
25