DMS-20RM-1-DC2-R-C Murata Power Solutions Inc, DMS-20RM-1-DC2-R-C Datasheet
DMS-20RM-1-DC2-R-C
Specifications of DMS-20RM-1-DC2-R-C
DMS-20RM-1-DC2-R-C Summary of contents
Page 1
... DMS-20RM rms voltmeters are available in a choice of three input ranges: 20Vac (with 0.01V resolution); 200Vac (0.1V resolution); and 0-300Vac (1V resolution). An input frequency range of 47-1kHz makes these voltmeters ideal for all ac voltage monitoring applications ...
Page 2
... DMS-20RM-2-AC1-R-C — 19.99 Vac DMS-20RM-3-AC1-R-C — 199.9 Vac — 300 Vac DMS-20RM-1-DC2-R-C 60 1000 Hz DMS-20RM-2-DC2-R-C DMS-20RM-3-DC2-R-C 2.5 reading per second A DMS-BZL4-C bezel assembly with sealing gasket is supplied with each meter. ±0.4%FS ±2 counts with 60Hz sine wave input IMPORTANT! voltmeters must be installed and serviced by qualifi ed technical personnel. ...
Page 3
... FRONT VIEW www.murata-ps.com/dpm DMS-20RM Series 2.01 (51.1) 1.00 (25.4) 0.800 0.040 (20.3) (1.02) 0.880 (22.4) 1.600 (40.6) BACK VIEW A TB1 - Power Supply CAL. CAL. CAL. TB2 - Input Signal email: sales@murata-ps.com 15 Mar 2011 MPM_DMS-20RM.A05 Page ...
Page 4
... Following the four-step sequence shown in Figure 3 — being careful not to apply excessive force or twisting motions — insert the DMS-20RM into the panel opening. When using the DMS-BZL4-C, install its sealing gasket positioned between the voltmeter’s front fl ange and panel front surface (see Mechanical Specifi ...