K3HB-XAD 100-240VAC Omron, K3HB-XAD 100-240VAC Datasheet - Page 13

no-image

K3HB-XAD 100-240VAC

Manufacturer Part Number
K3HB-XAD 100-240VAC
Description
PROCESS INDICATR DC CURRNT INPUT
Manufacturer
Omron
Series
K3HBr
Type
Process Meterr
Datasheet

Specifications of K3HB-XAD 100-240VAC

Measuring Range
0 ~ 199.99mA
Display Style
Green, Red Characters, Black Background
Display Type
LCD
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
5
Display Digits - Height
0.193" (4.90mm), 0.559" (14.20mm)
Backlight
Green, Red
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
100 ~ 240VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K3HB-XAD100-240VAC
K3HBXAD100240VAC
■ Input Ranges (Measurement Range and Accuracy)
Note: 1. The accuracy is for an ambient temperature of 23±5°C. For all ranges,10% or less of max. input ±0.1% FS.
The area shown in dark shading indicates the factory setting.
■ Load Cell Wiring Example
B-20
K3HB-VLC
Load Cell, mV
(mV)
Input type
B5
B6
2. The letters “rdg” mean “reading.”
B
Connected
Input type
terminals
200.000
150.000
100.000
−100.00
−150.00
−200.00
50.000
−50.00
Weighing Indicator
0.00
E2
E3
E4
E5
E6
E
A
B
C
D
Range
E2
199.99
a lc
0.00
E6
+10 V
0 V
a ud
b ud
c ud
d ud
+
Set value
+OUT
K3HB-V
E3
19.999
0.000
b lc
Load cell
0.00 to 199.99 mV
0.000 to 19.999 mV
±100.00 mV
±199.99 mV
E6
+IN
−IN
Measurement range
−OUT
−100.00
E4
100.00
c lc
E6
■ Scaling Example Using Range A
Indicated on the K3HB-V as 0 to 49N in the load cell specifications
(rated load 49N, recommended applied voltage 10 V, rated output 2
mV/V) (See note.)
Note: 2 mV/V indicates a load cell output of 2 mV for 1 V applied volt-
1 MΩ min.
Input impedance
E5
−199.99
199.99
age for the rated load (when using a load of 1 N). When the ap-
plied voltage is 10 V, the load cell output is 20 mV (2 mV × 10).
d lc
49 N
Display value
E6
20 mV
±0.1%rdg ± 1 digit max.
±0.1%rdg ± 5 digits max.
±0.1%rdg ± 3 digits max.
±0.1%rdg ± 1 digit max.
Input value
Accuracy
Scaling values:
inp.a1=000.00
dsp.a1=00000
inp.a2=020.00
dsp.a2=49000
dp decimal point position: 00.000
±200 V
overload (30 s)
instantaneous
Allowable