PAXLCL00 Red Lion Controls, PAXLCL00 Datasheet - Page 3

METER CURRENT LOOP 3 1/2-DIGIT

PAXLCL00

Manufacturer Part Number
PAXLCL00
Description
METER CURRENT LOOP 3 1/2-DIGIT
Manufacturer
Red Lion Controls
Series
PAX®LITEr
Type
Process Meter (4-20mA Loop)r
Datasheets

Specifications of PAXLCL00

Measuring Range
4-20mA Loop
Display Style
Red Characters, Black Background
Display Type
LED
Display Face Size
3.80" L x 1.95" W (96.5 x 49.5mm)
Display Digits
3.5
Display Digits - Height
0.560" (14.22mm)
Backlight
Without
Mounting Type
Panel Mount
Termination
Terminal Block
Voltage - Supply
85 V ~ 250 VAC
No. Of Digits / Alpha
3-1/2
Meter Function
Loop Current
Meter Range
4mA To 20mA / 10mA To 50mA
Digit Height
14.2mm
Power Consumption
6VA
Operating Temperature Range
0°C To +60°C
Supply Voltage Ac, Min
85V
Accuracy
±0.05% %
Connection Type
Cage-Clamp
Cut Out, Panel
3.62×1.77 "
Dimensions
4.2"L×3.8"W×1.95"H
Display Digit Height
0.56 "
Function
Ammeter
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
4 to 20/10 to 50 mA
Special Features
Multi-Range Unit
Standards
cULus Listed, CE Marked
Temperature, Operating
0 to 60 °C
Time, Response
1 Second to settle for step change
Voltage, Supply
85 to 250 VAC
Weight
0.65 lbs
Character Size
0.56"
Rohs Compliant
NA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
na, Lead free / RoHS Compliant
Other names
RLC112
1.
2. OVER-RANGE INDICATION: Indicated by blanking 3 least significant
3. POWER:
4. INPUT SENSITIVITY: (Numerical Readout Change/mA)
5. COMPLIANCE: Voltage drop across input at max. signal current, less than
6. INPUT RESISTANCE:
7. SCALING RANGE:
8. LINEARITY: ±(0.05% ±1 digit)
9. READING RATE: 2.5 updated readings/second, nominal.
10. RESPONSE TIME: 1 second to settle for step change.
11. LOW FREQUENCY NOISE REJECTION:
12. ENVIRONMENTAL CONDITIONS:
13. CERTIFICATIONS AND COMPLIANCES:
G
DISPLAY: 3 1/2-digit, 0.56" (14.2 mm) high, 7-segment LED, (-) minus sign
displayed when current or voltage is negative. Decimal points inserted before
1st, 2nd, or 3rd least significant digits by DIP switch selection.
digits.
AC Power: 85 to 250 VAC, 50/60 HZ, 6 VA
Isolation: 2300 Vrms for 1 min. between input and supply (300 V working
260 units/mA @ 4 to 20 mA input
105 units/mA @ 10 to 50 mA input
(max. allowable input current, 170 mA)
600 mV for both 4 to 20 and 10 to 50 mA ranges.
4 to 20 mA - 29.2 Ω
10 to 50 mA - 11.8 Ω
SPAN: 32 coarse steps (binary progression with 5 DIP switches) Each step
OFFSET: 16 coarse steps (binary progression with 4 DIP switches) with ±
Normal Mode Rejection: 63 dB @ 50/60 Hz
Common Mode Rejection: 100 dB, DC to 50/60 Hz
Operating Temperature: 0° to 60°C
Storage Temperature: -40° to 80°C
Operating and Storage Humidity: 85% max. relative humidity (non-
Span Temperature Coeff.: 100 PPM/°C
Offset Temperature Coeff.: 100 PPM/°C
Vibration According to IEC 68-2-6: Operational 5 to 150 Hz, in X, Y, Z
Shock According to IEC 68-2-27: Operational 30g’s (10g relay), 11 msec in
Altitude: Up to 2000 meters
SAFETY
UL Recognized Component, File # E179259, UL61010A-1, CSA C22.2 No. 61010-1
UL Listed, File # E137808, UL508, CSA C22.2 No. 14-M95
voltage).
providing approx. 8.125 numerical units/mA/step sensitivity for 4 to 20
mA input and 3.25 units/mA/step for 10 to 50 mA input.
switch to add or subtract offset. Each step adds or subtracts approximately
175 from the numerical display for a total offset range of ±2700.
condensing)
direction for 1.5 hours, 2g’s.
3 directions.
Recognized to U.S. and Canadian requirements under the Component
Recognition Program of Underwriters Laboratories, Inc.
LISTED by Und. Lab. Inc. to U.S. and Canadian safety standards
Type 4X Enclosure rating (Face only), UL50
ENERAL
M
ETER
S
PECIFICATIONS
14. EXCITATION SUPPLY: 24 VDC @ 50 mA max. Regulated and isolated.
15. CONNECTIONS: High compression cage-clamp terminal block
16. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 use. IP20 Touch
17. WEIGHT: 0.65 lbs (0.24 kg)
IECEE CB Scheme Test Certificate # US/8843A/UL
ELECTROMAGNETIC COMPATIBILITY
Emissions and Immunity to EN 61326: Electrical Equipment for
Measurement, Control and Laboratory use.
Notes:
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 4.5 inch-lbs (0.51 N-m) max.
safe. Installation Category II, Pollution Degree 2. One piece bezel/case.
Flame resistant. Panel gasket and mounting clip included.
Immunity:
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
Surge
RF conducted interference
Power frequency magnetic fields
Voltage dip/interruptions
Emissions:
Emissions
CB Scheme Test Report # 04ME11209-20041018
IEC 61010-1, EN 61010-1: Safety requirements for electrical equipment
IP65 Enclosure rating (Face only), IEC 529
IP20 Enclosure rating (Rear of unit), IEC 529
1. Criterion A: Normal operation within specified limits.
2. Criterion B: Temporary loss of performance from which the unit self-
Issued by Underwriters Laboratories, Inc.
for measurement, control, and laboratory use, Part 1.
recovers.
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 55011
Criterion A
4 kV contact discharge
8 kV air discharge
Criterion B
10 V/m
Criterion A
2 kV power
2 kV signal
Criterion A
1 kV L-L,
1 kV signal
Criterion A
3 V/rms
Criterion A
30 A/m
Criterion A
0.5 cycle
Class B
2 kV L&N-E power