3-1375055-1 TE Connectivity, 3-1375055-1 Datasheet

ASSY/SL 110 JK,CAT6,ELEC.IVORY

3-1375055-1

Manufacturer Part Number
3-1375055-1
Description
ASSY/SL 110 JK,CAT6,ELEC.IVORY
Manufacturer
TE Connectivity
Series
SL Seriesr
Datasheets

Specifications of 3-1375055-1

Product Type
Connector - Modular
Jack Type
RJ45
Wiring Pattern
Universal
Termination Style
110 Style Punch-Down
Keyed
No
Performance Category
Cat 6
Shielded
No
Number Of Positions
8
Netconnect Select System
No
Conductor O.d. (mm [in])
1.45 [0.057]
Mount Type
Panel Mount
Wire Range (solid) (mm [awg])
22-24
Wire Range (stranded) (mm² [awg])
24-26
110 Block Material
Polycarbonate
Contact Base Material
Beryllium Copper
Contact Plating, Mating Area, Material
Gold
Contact Plating, Mating Area, Thickness (µm [?in])
1.27 [50]
Housing Color
Electric Ivory
Housing Material
Polycarbonate
Ul Flammability Rating
UL 94V-0
Dust Cover
Without
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Converted to comply with RoHS directive
Packaging Method
Poly Bag
Packaging Quantity
25
1.
1.1.
1.2.
1.3.
2.
2.1.
2.2.
©2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. Company
All Rights Reserved
TE logo is a trademark.
SCOPE
Content
This specification covers perform ance, test and quality requirem ents for NETCONNECT* Category 3,
Category 5e and Category 6 SL Series unshielded 110 jacks, Category 5e and Category 6 SL Series
shielded 110 jacks and plugs. These assem blies are designed for installation into various outlet plates,
surface m ount boxes, panels, and other sim ilar type fittings. Jacks incorporate IDC term inals for
term inating both shielded or unshielded twisted pair com m unications cable. Jacks will accom m odate 22
- 24 AW G solid and 24 - 26 AW G stranded conductors. The m axim um conductor insulation diam eter is
1.45 m m [.057 in]. For large OD conductors 1.27 to 1.45 m m an external strain relief m ust be used. The
plugs accom m odate Category 6 cable and shielded or unshielded twisted pair cable with 23 - 24 AW G
solid, or 24 - 26 AW G stranded conductors. The m axim um conductor insulation diam eter is 1.00 m m
[.039 in] with a cable jacket diam eter between 4.7 and 7.0 m m [.185 and .276 in].
Qualification
W hen tests are perform ed on the subject product line, procedures specified in Figure 1 shall be used.
All inspections shall be perform ed using the applicable inspection plan and product drawing.
Successful qualification testing on the subject product line was com pleted on 01Nov02. The
Qualification Test Report num ber for this testing is 501-553. This docum entation is on file at and
available from Engineering Practices and Standards (EPS).
APPLICABLE DOCUM ENTS
The following docum ents form a part of this specification to the extent specified herein. Unless
otherwise specified, the latest edition of the docum ent applies. In the event of conflict between the
requirem ents of this specification and the product drawing, the product drawing shall take precedence.
In the event of conflict between the requirem ents of this specification and the referenced docum ents,
this specification shall take precedence.
TE Connectivity (TE) Docum ent
501-553: Qualification Test Report (NETCONNECT* SL Series Jacks and Category 6 Plugs)
Industrial Standards
!
!
!
!
!
EIA-364: Electrical Connector/Socket Test Procedures Including Environm ental Classifications
IEC 60068: Basic Environm ental Testing Procedures
IEC 60512: Electrom echanical Com ponents For Electronic Equipm ent; Basic Testing Procedures
and Measuring Methods Part 1: General
TIA/EIA-568-B.2: Com m ercial Building Telecom m unications Cabling Standard Part 2: Balanced
Twisted-Pair Cabling Com ponents
TIA-968-A: Telecom m unications, Telephone Term inal Equipm ent, Technical Requirem ents for
Connection of Term inal Equipm ent to the Telephone Network
| Indicates change
*Trademark
Product
Specification
NETCONNECT* SL Series Jacks and Category 6 Plugs
For latest revision, visit our website at www.te.com/documents.
For Regional Customer Service, visit our website at www.te.com
Other products, logos, and company names might be trademarks of their respective owners.
108-1990
11Mar11 Rev K
1 of 8
LOC B

Related parts for 3-1375055-1

3-1375055-1 Summary of contents

Page 1

... AW G solid and stranded conductors. The m axim um conductor insulation diam eter is 1. [.057 in]. For large OD conductors 1. external strain relief m ust be used. The plugs accom m odate Category 6 cable and shielded or unshielded twisted pair cable with solid stranded conductors. The m axim um conductor insulation diam eter is 1. ...

Page 2

... Application Specification (High Perform ance Modular Plug Connectors) ! 114-13035: Application Specification (8 Position Category 6 Modular Plug Connectors) ! 114-93006: Application Specification (8-Position Category 6 Shielded Modular Plug Connector) ! 408-8417: Instruction Sheet (SL Series 110 Connect Modular Jacks) ! 408-8602: Instruction Sheet (Shielded SL Series 110 Connect Modular Jacks) 3 ...

Page 3

... IEC 60512-9-1. Mate and unm ate plug and jack interface with latch inoperative for 750 cycles axim um rate of 500 (autom atic) or 300 (m anual) cycles per hour. IEC 60512-13-1. Measure force required to m ate plug and jack with latch depressed axim um rate of ...

Page 4

... Duration exposure shall inutes with an average transition rate of 3°C per m inute. IEC 60512-11-9. Subject m ated plug and term inated jack to 25 cycles between –40 and 70°C. IEC 60068-2-38. Subject m ated plug and term inated jack to 21 cycles (cycle tim e 24 hours) between 25 and 65° ...

Page 5

... Perform 100 cycles (terminations) on jack IDC’s before thermal shock, 33 additional cycles (terminations) on jack IDC’s after 50 temperature cycles of thermal shock, 33 cycles (terminations) on jack IDC’s after 7 days of humidity-temperature cycling, and 34 cycles (terminations) after 21 days of humidity/temperature cycling. (d) Precondition jack interface with 40 durability cycles. ...

Page 6

... SL Category 5e or Category 6 jack and Category 6 plug Category 5e or Category 6 jack and high perform ance plug Category 3 jack and 6 position plug. Test group 8, 6 position plug shall have no coring where pins 1 and 8 are located in receiving jack, as shown in TIA-968-A Figure 6.3. Test group 11 shall consist of 5 specim ens of shielded jacks and plugs ...

Page 7

... Millivolt drop (resistance) due to wire lengths shall be subtracted from all readings. Overall Term ination Resistance Measurem ent Points Term ination Tensile Strength Horizontal Pull Rev K Figure 3 Figure 4 108-1990 ...

Page 8

Rev K Figure 5 Term ination Tensile Strength Vertical Pull 108-1990 ...