4-641243-1 TE Connectivity, 4-641243-1 Datasheet
4-641243-1
Specifications of 4-641243-1
Related parts for 4-641243-1
4-641243-1 Summary of contents
Page 1
... The MTA-100 connector system is designed to be terminated to 28 AWG to 22 AWG wire, tin plated UL style 1007, 1061 or wire which specifies PVC insulation with temperature rating compatible with specified operating temperatures, see Figure 4. Wire shall meet application requirements specified in Application Specification 114-1019. Insulation diameters are: .050 inch maximum outside diameter for mass termination and ...
Page 2
... Ratings ! Voltage: 250 volts AC ! Current: See Figure 4 for applicable current carrying capability ! Temperature: -55 to 105° C 3.4. Performance and Test Description Product is designed to meet the electrical, mechanical and environmental performance requirements specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions per Test Specification 109-1 ...
Page 3
... TE Spec 109-27. Manually mate and unmate samples with friction lock header for 25 cycles. TE Spec 109-42, Condition A. Measure force necessary to mate samples with friction lock header from point of initial contact to depth of .200 inch at maximum rate of .5 inch per minute. ...
Page 4
... Physical shock Durability Mating force Unmating force Thermal shock Humidity-temperature cycling Temperature life Mixed flowing gas (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. (c) Tin-lead plated samples. (d) Gold plated samples. (e) Discontinuities shall not be measured. Energize at 18 Test Specification 109-151. ...
Page 5
... Test group 5 shall consist position standard tin-lead plated samples terminated to 28 AWG wire position standard tin-lead plated samples terminated to 24 AWG wire; and 6, 10 position standard tin-lead plated samples terminated to 22 AWG wire. All samples shall be unmated and unmounted ...
Page 6
Termination resistance equals millivolts divided by test current less resistance of 2 NOTE inches of wire. (b) After wave soldering, the boards and posts shall be cleaned to remove all flux and contaminates. Temperature & Termination Resistance Measurement Points ...
Page 7
... To determine acceptable current carrying capacity for percentage connector loading and wire NOTE gage indicated, use the Multiplication Factor (F) from the above chart and multiply it times the Base Rated Current for a single circuit at maximum ambient operating temperature as shown in Figure 4A. Rev H Figure 4A Current Carrying Capability ...
Page 8
PC Board Used For Termination Resistance Dry Circuit Rev H PC Board Used For Current Rating Figure 5 Printed Circuit Test Boards 108-1050 ...
Page 9
Rev H Figure 6 Termination Tensile Strength 108-1050 ...