LTC1864LACS8 Linear Technology, LTC1864LACS8 Datasheet - Page 4

IC ADC 1CH 16B 3V 150KSPS 8SOIC

LTC1864LACS8

Manufacturer Part Number
LTC1864LACS8
Description
IC ADC 1CH 16B 3V 150KSPS 8SOIC
Manufacturer
Linear Technology
Datasheet

Specifications of LTC1864LACS8

Number Of Bits
16
Sampling Rate (per Second)
150k
Data Interface
MICROWIRE™, Serial, SPI™
Number Of Converters
1
Power Dissipation (max)
400mW
Voltage Supply Source
Single Supply
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (0.154", 3.90mm Width)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC1864LACS8
Manufacturer:
LT
Quantity:
10 000
LTC1864L/LTC1865L
RECO
full operating temperature range, otherwise specifications are T
SYMBOL PARAMETER
V
f
t
t
t
t
t
t
t
t
t
t
range, otherwise specifications are T
Conditions, unless otherwise noted.
TI I G CHARACTERISTICS
SYMBOL
t
f
t
t
t
t
t
t
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: All voltage values are with respect to GND.
Note 3: Integral nonlinearity is defined as deviation of a code from a
straight line passing through the actual endpoints of the transfer curve.
The deviation is measured from the center of the quantization band.
4
SCK
CYC
SMPL
suCONV
hDI
suDI
WHCLK
WLCLK
WHCONV
WLCONV
hCONV
CONV
SMPL(MAX)
dDO
dis
en
hDO
r
f
CC
W
U
Supply Voltage
Clock Frequency
Total Cycle Time
Analog Input Sampling Time (Note 5)
Setup Time CONV↓ Before First SCK↑
(See Figure 1)
Hold Time SDI After SCK↑
Setup Time SDI Stable Before SCK↑
SCK High Time
SCK Low Time
CONV High Time Between Data
Transfer Cycles
CONV Low Time During Data Transfer
Hold Time CONV Low After Last SCK↑
W W
PARAMETER
Conversion Time (See Figure 1)
Maximum Sampling Frequency
Delay Time, SCK↓ to SDO Data Valid
Delay Time, CONV↑ to SDO Hi-Z
Delay Time, CONV↓ to SDO Enabled
Time Output Data Remains
Valid After SCK↓
SDO Rise Time
SDO Fall Time
E DED OPERATI G CO DITIO S
U
A
= 25°C. V
CC
U
CONDITIONS
LTC1864L
LTC1865L
LTC1865L
LTC1865L
f
f
= 2.7V, V
CONDITIONS
C
C
C
C
C
SCK
SCK
The
LOAD
LOAD
LOAD
LOAD
LOAD
= f
= f
= 20pF
= 20pF
= 20pF
= 20pF
= 20pF
SCK(MAX)
SCK(MAX)
denotes specifications which apply over the full operating temperature
REF
U
A
= 2.5V, f
= 25°C.
Note 4: Channel leakage current is measured while the part is in sample
mode.
Note 5: Assumes f
not have to be clocked during this time if the SDO data word is not
desired. In the case of the LTC1865L a minimum of 2 clocks are required
on the SCK input after CONV falls to configure the MUX during this time.
SCK
U
= f
SCK(MAX)
The
SCK
as defined in Recommended Operating
= f
denotes specifications which apply over the
SCK(MAX)
In the case of the LTC1864L SCK does
16 • SCK + t
t
45%
45%
MIN
CONV
MIN
150
2.7
DC
16
14
60
30
30
16
26
5
LTC1864L/LTC1865L
LTC1864L/LTC1865L
TYP
CONV
TYP
3.7
45
55
35
15
25
12
MAX
MAX
4.66
3.6
120
120
sn18645L 18645Lfs
55
60
8
UNITS
1/f
1/f
UNITS
MHz
SCK
SCK
SCK
SCK
SCK
kHz
µs
ns
ns
ns
µs
ns
µs
ns
ns
ns
ns
ns
ns
ns
V