521596-1 TE Connectivity, 521596-1 Datasheet - Page 2

187 ULTRA-POD FLAG 22-18 BR

521596-1

Manufacturer Part Number
521596-1
Description
187 ULTRA-POD FLAG 22-18 BR
Manufacturer
TE Connectivity
Datasheets

Specifications of 521596-1

Proprietary Name
Ultra-Pod
Receptacle Style
Flag
Mating Area Interface Dimensions (mm [in])
4.75 x 0.51 [.187 x .020]
Insulation Diameter (mm [in])
1.52-2.79 [.060-.110]
Insertion Force
Normal
Finish
None
Insulation Support
Insulation Support
Color
Natural
Fully Insulated
Yes
Wire Range (mm [awg])
0.30-0.90² [22-18]
Ul Flammability Rating
UL 94V-0
Housing Material
Nylon
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Packaging Method
Strip
3.3.
3.4.
3.5.
Rev A
Examination of product.
Low level contact resistance.
Withstanding voltage, Test
Condition A.
Withstanding voltage, Test
Condition C.
Withstanding voltage, receptacle,
tab entry position.
Temperature rise vs current.
Current cycling.
Ratings
!
!
Performance and Test Description
Product is designed to meet the electrical, mechanical and environmental performance requirements
specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental
conditions per EIA-364.
Test Requirements and Procedures Summary
Test Description
Voltage: 600 volts AC
Temperature:
-40 to 105
Meets requirements of product
drawing and Application
Specification 114-2124.
1 milliohm maximum initial.
5 milliohms maximum final.
1 minute hold with no breakdown or
flashover.
1 minute hold with no breakdown or
flashover.
1 minute hold with no breakdown or
flashover.
30
rise at specified current.
45
rise at specified current.
See Figure 5.
/
C
/
/
C initial maximum temperature
C final maximum temperature
Figure 1 (cont)
ELECTRICAL
Requirement
Visual and dimensional (C of C)
inspection per product drawing.
EIA-364-23.
Subject specimens to 100
milliamperes maximum and 20
millivolts maximum open circuit
voltage.
EIA-364-20, Condition I; and UL
310 600 Volt Rating.
3400 volts AC at sea level.
Test wired specimens in number 12
lead shot after coating end with
insulating material.
EIA-364-20, Condition I; and UL
310 600 Volt Rating.
3000 volts AC at sea level.
Test specimens on flat metal plate.
See Figure 3.
EIA-364-20, Condition I.
1000 volts AC at sea level.
Test specimens on flat metal plate.
See Figure 4.
EIA-364-70, Method 1.
Stabilize at a single current level
until 3 readings at 5 minute
intervals are within 1
See Figure 5.
EIA-364-55.
Subject mated contacts to 500
cycles of 45 minutes ON and 15
minutes OFF.
Procedure
/
C .
108-2215
2 of 6

Related parts for 521596-1