793-5607 WAGO, 793-5607 Datasheet - Page 7

WMB MKR 5-5.2MM 51-100 (2X)

793-5607

Manufacturer Part Number
793-5607
Description
WMB MKR 5-5.2MM 51-100 (2X)
Manufacturer
WAGO
Series
WMBr
Datasheet

Specifications of 793-5607

Rohs Compliant
YES
Accessory Type
Terminal Block Marker
Legend
51 To 100
Legend Color
Black
Marker Color
White
Background Color
White
For Use With
Terminal Blocks And Connectors
The special design of the TOPJOB
staggered jumpers allows two
jumpers to be used in each jumper
slot of the 2002 Series TOPJOB
rail-mounted terminal blocks and
2003 Series multilevel installation
terminal blocks. This means that
four different potentials can be
commoned simultaneously using
rail-mounted terminal blocks with dual jumper slots.
Simply commoned with staggered jumpers
Simply jumpered
with step-down jumpers
with push-in type jumper bars
( 1 )
( 1 )
®
®
S
S
When commoning on the open side of the block using an end plate, terminal blocks
16 mm
below the rated cross section and terminal blocks 6 (AWG 8) / 4 (AWG 10) and 2.5 mm
(AWG 12) can be commoned with terminal blocks rated one size below the rated cross section.
2
The step-down jumper 2016-499 is suitable for commoning 16 /10 mm
terminal blocks with 10 / 6 / 4 / 2.5 mm
The step-down jumper 2006-499 is suitable for commoning 6 / 4 mm
terminal blocks with 4 / 2.5 / 1.5 mm
An end plate (1) must always
be applied between the ter-
minal blocks to be commo-
ned with step-down jum-
pers.
(AWG 4) and 10 mm
Insert the staggered jumpers so that the red
lines of both jumpers are facing each other.
7
2
(AWG 6) can be commoned with terminal blocks rated two sizes
2
(AWG 10 / 12 / 14) terminal blocks.
For example, terminal blocks 16 mm
can be commoned with terminal blocks 6 mm
(AWG 8) (see ill.) or terminal blocks 10 mm
(AWG 6) with terminal blocks 4 mm
When commoning on the back side of the
block using an end plate, terminal blocks can
be commoned with terminal blocks rated two
sizes below the rated cross section. For exam-
ple, 16 mm
commoned with terminal blocks 6 mm
or terminal blocks 6 mm
blocks 2.5 mm
2
Note
The total current flowing cannot exceed
the rating of the step-down jumper or
push-in type jumper bar.
(AWG 6 / 8 / 10 / 12) terminal blocks.
2
(AWG 4) terminal blocks can be
2
(AWG 12) (see ill.).
Custom staggered jumpers are
created by breaking off indivi-
dual jumper contacts. Make
sure that only one contact lug
is in contact with the terminal
block. See also page 28.
2
(AWG 8) with terminal
2
2
(AWG 8 / 10)
(AWG 4 /6)
2
2
(AWG 10).
(AWG 4)
2
(AWG 8)
2
2
2

Related parts for 793-5607