22.34.0.012.4320 FINDER, 22.34.0.012.4320 Datasheet

no-image

22.34.0.012.4320

Manufacturer Part Number
22.34.0.012.4320
Description
RELAY, CONTACTOR, 25A, 4NO, 12V
Manufacturer
FINDER
Datasheet

Specifications of 22.34.0.012.4320

Relay Type
Modular
Coil Voltage Vac Nom
12V
Coil Voltage Vdc Nom
12V
Contact Current Max
25A
Contact Voltage Ac Nom
250V
Contact Configuration
4NO
Nom Operating Power
2VA
Relay Mounting
DIN
Rohs Compliant
Yes
Features
25 A modular contactor - 2 pole
22.32...1xx0 / 22.32...4xx0
Screw terminal
* Contact gap ≥ 3 mm for NO contacts only;
For outline drawings see page 7
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage
Rated load AC1 / AC-7a (per pole @ 250 V) VA
Rated current AC3 / AC-7b
Rated load AC15 (per pole @ 230 V)
Single-phase motor rating (230 V AC)
Rated current AC-7c
230 V lamps rating: incandescent or halogen W
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Contact material
Coil specification
Nominal voltage (U
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC-7a
Operate/release time
Insulation between coil and contacts (1.2/50 μs) kV
Ambient temperature range
Protection category
Approvals (according to type)
17.5 mm wide
NO contact gap ≥ 3 mm, double break
Continuous duty for the coil and contacts
AC/DC silent coil (with varistor protection)
Protective separation (reinforced insulation)
between coil and contacts
Mechanical and LED indicators as standard
Auto-On-Off selector version available
AgNi and AgSnO
Compliant with EN 61095: 2009
Auxiliary contact module available,
quick-assembly with the main contactor
(1 NO + 1 NC and 2 NO versions)
35 mm rail (EN 60715) mount
electromagnetic ballast compens. fluorescent tubes W
NC contacts ≥ 1.5 mm
electronic ballast fluorescent tubes W
compact fluorescent (CFL) W
2
N
contact versions available
)
V DC/AC (50/60 Hz)
DC/AC (50/60 Hz)
DC/AC (50/60 Hz)
DC/AC (50/60 Hz)
VA (50 Hz)/W
mW (V/mA)
cycles
cycles
V AC
kW
VA
ms
°C
A
A
A
A
12 - 24 - 48 - 60 - 120 - 230
AgNi contacts, specifically
intended for resistive and
slightly inductive loads as
well as for motor loads
22.32.0.xxx.1xx0
1,000 (10 / 10)
(0.8 …1.1) U
2 NO, 3 mm * (or 1 NO + 1 NC or 2 NC)
250 / 440
–20…+50
25 / 80
25/5/1
70 · 10
30 / 20
0.4 U
0.1 U
2 · 10
2 /2.2
(x3x0)
6,250
1,800
2 NO
AgNi
IP20
10
1
6
N
N
6
3
N
1 NO + 1 NC
(x5x0)
22 Series - Modular contactors 25 A
12 - 24 - 48 - 60 - 120 - 230
AgSnO
intended for lamp loads and
for high inrush current loads
22.32.0.xxx.4xx0
1,000 (10 / 10)
(0.8 …1.1) U
2
250 / 440
–20…+50
contacts, specifically
25 / 120
AgSnO
30 · 10
25/5/1
30 / 20
2 / 2.2
0.4 U
0.1 U
2 · 10
6,250
1,800
2,000
(x4x0)
IP20
200
800
500
2 NC
10
10
1
6
N
N
6
2
3
N
1

Related parts for 22.34.0.012.4320

22.34.0.012.4320 Summary of contents

Page 1

Features 25 A modular contactor - 2 pole 17.5 mm wide • NO contact gap ≥ 3 mm, double break • Continuous duty for the coil and contacts • AC/DC silent coil (with varistor protection) • Protective separation (reinforced insulation) ...

Page 2

Features 25 A modular contactor - 4 pole 35 mm wide • NO contact gap ≥ 3 mm, double break • Continuous duty for the coil and contacts • AC/DC silent coil (with varistor protection) • Protective separation (reinforced insulation) ...

Page 3

Ordering information Exemple: 22 series, modular contactor contacts, coil 230 V AC/DC, AgSnO Series Type modular contactor range Number of contacts pole pole ...

Page 4

Technical data Insulation Rated insulation voltage Pollution degree Insulation between coil and contact set Type of insulation Overvoltage category Rated impulse voltage Dielectric strength Insulation between adjacent contacts Type of insulation Overvoltage category Rated impulse voltage Dielectric strength Insulation between ...

Page 5

Contact specification Ratings and utilization categories according to EN 61095 : 2009 Utilization Typical Load category applications characteristics Slightly cos ϕ = 0.8 AC-7a inductive loads cos ϕ = 0.45 AC-7b Motor loads making Compensated cos ...

Page 6

Wiring diagrams Line and neutral switched Type 22. Series - Modular contactors 25 A Type 22.32 Line only switched Type 22.34 ...

Page 7

Outline drawings Type 22.32 Screw terminal Type 22.34 Screw terminal Type 022.33 / 022.35 Screw terminal 22 Series - Modular contactors 25 A Type 22.32 + 022.33 / 022.35 Screw terminal Type 22.34 + 022.33 / 022.35 Screw terminal 7 ...

Page 8

Auxiliary module 022.33 / 022.35 22.32 + 022.33 / 022.35 22.34 + 022.33 / 022.35 Contact specification Contact configuration Conventional free air thermal current I th Rated current AC15 (230 V) Electrical life at rated load Contact material Short circuit ...

Page 9

Accessories Adaptor for panel mounting (for 22.32 type), plastic, 17.5 mm wide 020.01 Adaptor for panel mounting (for 22.34 type), plastic wide 011.01 Sheet of marker tags, plastic, 72 tags, 6x12 mm 060.72 Identification tag, plastic, 1 tag, ...

Page 10

...

Related keywords