CAT5401WI-25-T1 ON Semiconductor, CAT5401WI-25-T1 Datasheet - Page 9

no-image

CAT5401WI-25-T1

Manufacturer Part Number
CAT5401WI-25-T1
Description
IC POT DPP QUAD 64TAP SPI 24SOIC
Manufacturer
ON Semiconductor
Datasheet

Specifications of CAT5401WI-25-T1

Taps
64
Resistance (ohms)
2.5K
Number Of Circuits
4
Temperature Coefficient
300 ppm/°C Typical
Memory Type
Non-Volatile
Interface
SPI Serial
Voltage - Supply
2.5 V ~ 6 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-SOIC (7.5mm Width)
Resistance In Ohms
2.5K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Wiper Control and Data Registers
Wiper Control Register (WCR)
Registers, one for each potentiometer. The Wiper Control
Register output is decoded to select one of 64 switches along
its resistor array. The contents of the WCR can be altered in
four ways: it may be written by the host via Write Wiper
Control Register instruction; it may be written by
transferring the contents of one of four associated Data
Registers via the XFR Data Register instruction, it can be
modified one step at a time by the Increment/decrement
instruction (see Instruction section for more details).
Finally, it is loaded with the content of its data register zero
(DR0) upon power−up.
its contents when the CAT5401 is powered−down. Although
the register is automatically loaded with the value in DR0
upon power−up, this may be different from the value present
at power−down.
Data Registers (DR)
Registers. These can be read or written directly by the host.
Data can also be transferred between any of the four Data
Table 12. INSTRUCTION SET
Read Wiper Control
Register
Write Wiper Control
Register
Read Data Register
Write Data Register
XFR Data Register to
Wiper Control Register
XFR Wiper Control
Register to Data
Register
Global XFR Data
Registers to Wiper
Control Registers
Global XFR Wiper
Control Registers to
Data Register
Increment/Decrement
Wiper Control Register
Read Status (WIP bit)
The CAT5401 contains four 6−bit Wiper Control
The Wiper Control Register is a volatile register that loses
Each potentiometer has four 6−bit non−volatile Data
Instruction
I3
1
1
1
1
1
1
0
1
0
0
I2
0
0
0
1
1
1
0
0
0
1
(Note: 1/0 = data is one or zero)
I1
0
1
1
0
0
1
0
0
1
0
I0
1
0
1
0
1
0
1
0
0
1
1/0
1/0
1/0
1/0
1/0
1/0
Instruction Set
R1
0
0
0
0
http://onsemi.com
R0
1/0
1/0
1/0
1/0
1/0
1/0
0
0
0
0
WCR1/ P1
9
1/0
1/0
1/0
1/0
1/0
1/0
1/0
0
0
0
Registers and the associated Wiper Control Register. Any
data changes in one of the Data Registers is a non−volatile
operation and will take a maximum of 5 ms.
Write In Process
nonvolatile memory when the CS input goes HIGH after a
write sequence is received. The status of the internal write
cycle can be monitored by issuing a Read Status command
to read the Write in Process (WIP) bit.
Instructions
These instructions are:
The contents of the Data Registers are saved to
Four of the nine instructions are three bytes in length.
Read Wiper Control Register – read the current wiper
position of the selected potentiometer in the WCR
Write Wiper Control Register – change current wiper
position in the WCR of the selected potentiometer
Read Data Register – read the contents of the selected
Data Register
Write Data Register – write a new value to the
selected Data Register
Read Status – Read the status of the WIP bit which
when set to “1” signifies a write cycle is in progress.
WCR0/ P0
1/0
1/0
1/0
1/0
1/0
1/0
1/0
0
0
1
Read the contents of the Wiper Control
Register pointed to by P1−P0
Write new value to the Wiper Control
Register pointed to by P1−P0
Read the contents of the Data Register
pointed to by P1−P0 and R1−R0
Write new value to the Data Register
pointed to by P1−P0 and R1−R0
Transfer the contents of the Data
Register pointed to by P1−P0 and
R1−R0 to its associated Wiper Control
Register
Transfer the contents of the Wiper
Control Register pointed to by P1−P0 to
the Data Register pointed to by R1−R0
Transfer the contents of the Data
Registers pointed to by R1−R0 of all four
pots to their respective Wiper Control
Registers
Transfer the contents of both Wiper
Control Registers to their respective data
Registers pointed to by R1−R0 of all four
pots
Enable Increment/decrement of the
Control Latch pointed to by P1−P0
Read WIP bit to check internal write
cycle status
Operation

Related parts for CAT5401WI-25-T1