Specifications of 077-05GA-SJSJ-C7

Meter Function
AC Voltmeter
Meter Range
0-600 V
Meter Size/dimensions
4-1/2 In
Scale Length
175.2mm
Meter Shape
Square
Voltage Meter Range
0-600 VAC
Display Accuracy ±
1%
Barrel Size
4"
Rohs Compliant
NA
070 Series ANSI Switchboard Meters
Features
Rugged Hi-Q taut-band suspension
Accuracy class 1
JIS dimensioned product available
on request
Benefits
Meets all the requirements of
ANSI-C39.1 (1981)
Parallax error-free platform dials
Bump, Shock and vibration proof
Customised options and features
Applications
Switchgear
Distribution systems
Generator sets
Control panels
Energy management
Building management
Utility power monitoring
Process control
Motor control
Approvals
UL approvals file No: E87815
CSA approvals file No: LR99712-1
ABS American Bureau of Shipping
approvals 93-LD 17806-X
ISSeP Institute Scientifique de Service
Public approvals 97D.101.226x
This high quality range of Switchboard instruments complies with the American
specification ANSI-C39.1 (1981) accuracy class 1. Available in 4
their rugged design characteristics suit the most demanding of environmental
applications. This extensive range of analogue and digital/analogue meters utilise a
high shock oil dampened movement, and provide 1% accuracy for all RMS AC and
DC ranges. The range offers various customised options and features.
Description
070 series offers two case sizes, 4
Model 078 is high shock hermetically sealed and all models have heavy gauge
pressed steel cases. Mounting is by four integral studs.
Models 075 & 077 are a one piece flame retardant polycarbonate moulding with a
matt black finished bezel area, and a specially contoured window to minimise
reflection from adjacent light sources. Model 079 has a black pressed steel bezel with
a toughened glass window, and Model 078 has a die-cast bezel and a projecting
moulded toughened glass window, which incorporates a gas tight zero adjuster.
Scales are 240° moving iron and 250° moving coil with parallax error-free platform
dials. Standard dials are matt white with black printed scales and bar knife-edge
pointers. Black dials with white or yellow scales and pointers are also available.
General options include supplementary red pointer (075 & 077), slave pointer,
calibration for non standard ambient temperatures, special scales, trim
potentiometers, and Illuminated dials with white or red light sources.
Specification
Dimensions
Dimension E varies with measured parameter - see product code table overleaf.
1 – 4 Fixing holes Ø 8mm. 2 – 1/4-28 UNF fixing studs. 3 – 10-32 UNF Terminals (M5
screw clamp terminal on model 075).
Performance:
Accuracy:
Terminals:
Dielectric Voltage:
Response Time:
Overshoot:
Standard Calibration:
Operating Temperature:
Storage Temperature:
Extreme Temp Range:
Enclosure Integrity:
Fixing on Panel:
Approvals:
Model
075
077
078
079
103
103
103
229
Dia
Panel Cut-out
30
86
86
86
86
A
ANSI C39.1 (1981)
Class 1
10-32 UNF terminals (M5 screw clamp terminal for
Model 075)
Withstand test 2.3kV for 1 minute
Approximately 2.5 seconds to full scale (077 and 078)
and 3.5 seconds (079)
33% maximum
23°C
0°C to +40°C. Model 078: -40°C to +70°C.
-10°C to +50°C
-20°C -to +65°C
Models 075/077/079 to IP54(NEMA 3S) splash proof
IP55 (NEMA 4) hoseproof is an optional extra
Model 078 to IP67 (NEMA 6 & 6P)
4 integral
EMC and LVD, UL, CSA, ABS and ISSep Approvals
43
43
43
43
B
1
/
2
" (Models 075, 077 & 078) and 8
1
/
View
4
Rear
110
110
110
229
-28 UNF fixing studs
C
17
17
17
17
D
E
-
-
-
-
1
/
2
" and 8
3
/
4
" (Model 079).
30
30
30
30
F
3
/
4
" case sizes,
101
101
101
101
G

Related parts for 077-05GA-SJSJ-C7

077-05GA-SJSJ-C7 Summary of contents

Page 1

... Model 078 is high shock hermetically sealed and all models have heavy gauge pressed steel cases. Mounting is by four integral studs. Models 075 & 077 are a one piece flame retardant polycarbonate moulding with a matt black finished bezel area, and a specially contoured window to minimise reflection from adjacent light sources ...

Page 2

... Frequencies 45/55,55/65,45/65, 47/53, 57/63, 360/440. *** Using transformer box 855-954 **** Nominal voltage to be specified For specification and connection diagrams, please refer to equivalent models in 240 Series DIN Panel Meter section. Replace 244 with 077 etc., e.g. 244-210 becomes 077-210. Case Code Ranges 075 077 0.5-10A ...

Page 3

... AC instruments are available with true RMS converting circuit or RMS compensated rectifier. Some types of frequency meters can be damaged by transient supply voltage spikes. Crompton 077-41 frequency meters can withstand, without damage, 10 successive applications of transient spikes of 1250 volts. The range offers UL and CSA approvals. JIS dimensioned products are available on request. Specification – ...

Page 4

... Product Code – A.C. Overload Ammeters - True RMS Reading*** Self contained 40/70Hz (Accuracy ±1%) 5/30A TO SUIT 077-086A-LS**-C6 077 moving iron ammeters available as listed above Rated 5A for standard C.T’s with 6 x full scale. Overload portion of the scale is not subject to the accuracy guarantee. • UL recognised File # E87815 ...

Page 5

... Other scales are available *** Case types 077/078/079 use 10-32 UNF terminals. For M5 screw clamp terminals stipulate case type 075 ...

Page 6

... Other scales are available ** Specify scale required *** Case types 077/078/079 use 10-32 UNF terminals. For M5 screw clamp terminals stipulate case type 075 ...

Page 7

... Product Codes – Instantaneous A.C. Voltmeter*** with Instantaneous Maximum Reading Slave Pointer 150V TO SUIT P.T. 077-05XA-PZ**-C6 250V TO SUIT P.T 077-05XA-RS**-C6 300V TO SUIT P.T 077-05XA-RX**-C6 077 moving iron ammeters and voltmeters available as listed above. • UL recognised File # E87815 + CSA Approved File # LR52592 ⁄ " Square Flange ...

Page 8

... Other scales are available ** Specify scale required. *** Other mV ratings and scale options available upon request. **** Case types 077/078/079 use 10-32 UNF terminals. For M5 screw clamp terminals stipulate case type 075. D.C. Ammeters Product Codes – Self Contained (Accuracy ±1%)**** 4 1 ⁄ ...

Page 9

... Other scales are available ** Specify scale required *** Case types 077/078/079 use 10-32 UNF terminals. For M5 screw clamp terminals stipulate case type 075 ...

Page 10

... Dual Range - Thermal Instantaneous 3/6A - with 20% overload scale 2.5/5A - without 20% overload scale 6/12A with 20% overload scale and internal limiting C.T. 5/10A - without 20% overload scale with internal limiting C.T. •077-16FU-LV Instantaneous Maximum Demand Ammeter with Slave Pointer Designed to be compatible with other 4 enhances panel appearance and indicates maximum instantaneous values of load current ...

Page 11

... Power Factor influence: Accuracy maintained 0.1 lag to 0.1 lead Enclosure code: 077: IP54 optional IP55 078: IP67 079: IP54 optional IP55 Response Time: 077,078: approximately 2.5 seconds 079: approximately 3.5 seconds Dielectric test: Live parts to case including panel 2600V RMS for 1 minute 40 ...

Page 12

Series ANSI Switchboard Meters Wattmeter/Varmeter Scale Selector Guide PRIMARY POTENTIAL 120 TRANSFORMER VOLTAGE (1:1) SYSTEM VOLTAGE 3 PHASE 3 WIRE (L-L) 120 SYSTEM VOLTAGE 3 PHASE 4 WIRE (L-N) 69 CURRENT TRANSFORMER RATIO NORMAL 5KW 25/5 MAX. 6 (5:1) ...

Page 13

Series ANSI Switchboard Meters Wattmeter/Varmeter Scale Selector Guide PRIMARY POTENTIAL 12KV 14.4KV TRANSFORMER VOLTAGE (100:1) (120:1) SYSTEM VOLTAGE 3 PHASE 3 WIRE (L-L) 12KV 14.4KV SYSTEM VOLTAGE 3 PHASE 4 WIRE (L-N) 6900 8300 CURRENT TRANSFORMER RATIO NORMAL 500KW ...

Page 14

... Taut Band. Integral transducer. Accuracy 1.0%. 50/60Hz 120V TO SUIT •/+077-31LA-QQ 208V TO SUIT •/+077-31LA-QR**- 240V TO SUIT 077-31LA-QS 380V TO SUIT 077-31LA-QX 480V TO SUIT 077-31LA-QT** For connection diagram please see Fig. 32 page 61. Product Codes – 21⁄2 element, transformer rated. 50/60Hz. Taut Band. Integral transducer. Accuracy 1.0%.50/60Hz ...

Page 15

... Standard Case Sealed Case Hi-Shock Catalogue No. Catalogue No. 078-45RJ-**QF-PQ 078-45RJ-**QE-PQ 078-45RJ-**QG- ⁄ " Square Flange 2 Standard Case Catalogue No. 077-45TA-••PM 8 ⁄ " Square Flange 3 4 Sealed Case Hi-Shock Standard Case Catalogue No. Catalogue No. Not available Not available * Other ranges available upon request - Consult Factory ...

Page 16

... Square Flange 2 Rating Standard Case Catalogue No. 100/150V 50/60Hz 077-12PA-P2C6 151/300V 50/60Hz 077-12PA-P3C6 301/500V 50/60Hz 077-12PA-P4C6 For connection diagrams please see Fig. 1 page 58. D.C. Indicators for Tachometer Generators Product Code 4 1 ⁄ ...

Page 17

... Voltage circuits 25% indefinitely. Burdens: Each current circuit, 1.5VA approx Each voltage circuit 1VA approx Measuring systems 077-427 - wire Ranges available: Lag 0.5-1 - 0.5 lead power factor Lag 0.2-1 - 0.8 lead power factor JIS dimension product available on request. Instruments may be used on loads down to 20% of current rating and between 90% and 110% of voltage rating. Product Codes – ...

Page 18

... For connection diagrams please see Fig & 7 page 58. Rotating iron 360° products are only suitable for use on 50 and 60 Hz systems. 3 Phase 4 Wire Power Factor Meters are connected L-L ie. 120V L-N system will be rated at 208V L-L. 47 077-132 077-136 V A 3380 0.043 ...

Page 19

... Square Flange 1 2 Rating Scaling* Standard Case Catalogue No. 120V 50Hz SLOW FAST •/+077-145A-PRAE-C5 120V 60Hz SLOW FAST •/+077-146A-PRAE-C6 120V 400Hz SLOW FAST 077-144A-PRAE-C4 For connection diagrams please see Fig. 10 page 59. Alternate voltage of 240V, use code RR instead of PR. ...

Page 20

... In the 0.77-14G and 0.77-14H models, the generator voltage is free to track the bus voltage (+ the voltage difference preset) over the input voltage range. In the 077- 14L and 077-14D models, the generator voltage is to match the nominal input (bus) voltage specified (within the voltage difference preset). ...

Page 21

... Case types 077/078/079 use 10-32 UNF terminals. For M5 screw clamp terminals stipulate case type 075 ** Specify scale. Input: 1mA D.C. for 4/20mA change “FA” to “HG” ⁄ " Square Flange 8 3 ⁄ ...

Page 22

... Available in side, center, or off-set zero versions the 077-DI can accept A.C. Current, Voltage, Frequency, Watts, VArs and Phase Angle or D.C.Current and Voltage direct inputs as well as a wide range of transducer outputs making it suitable for a variety of other applications including low-load current, temperature, speed, watt/vars,percent and level ...

Page 23

... Z2 - 130 Volts D. Volts D. 115 Volts A. Volts D.C. * Other scalings available. ** Specify power supply voltage, for the code, see Power Supply Codes table. *** Case types 077/078/079 use 10-32 UNF terminals. For M5 screw clamp terminals stipulate case type 075 52 Scaling* Catalogue No. 077-DIWA-KAKA-C6-** 077-DIWA-KDKD-C6-** ...

Page 24

... Scaling* Catalogue No. 45-55Hz 077-DZLA-PNAG-AG 46-54Hz 077-DZLA-PNAH-AH 45-65Hz 077-DZLA-PNAJ-AJ 50-70Hz 077-DZLA-PNAL-AL 55-65Hz 077-DZLA-PNAN-AN 56-64Hz 077-DZLA-PNAO-AO 58-62Hz 077-DZLA-PNAT-AT 350-450Hz 077-DZLA-PNBH-BH 360-440Hz ...

Page 25

... PO - 115 Volts A. Volts D.C. * Other scales are available. ** Specify power supply voltage, for the code, see Power Supply Codes table. *** Case types 077/078/079 use 10-32 UNF terminals. For M5 screw clamp terminals stipulate case type 075 **** Specify input and scaling 54 Scaling* Catalogue No. ...

Page 26

... Specify power supply voltage, for the code, see Power Supply Codes table. 55 Scaling* Catalogue No. 077-DIAA-EY 077-DICA-GB 077-DICA-GM 077-DICA-FM Scaling* Catalogue No. 077-DIAA-GM 077-DIAA-HG 077-DIAA-HZ Scaling* Catalogue No. 077-DIAA-FAFA-** 077-DIAA-FGFG-** 077-DIAA-FXFY-** 077-DIAA-GZGZ-** 077-DIAA-HFHF-** 077-DIAA-HMHM-** 077-DIAA-HYHY-** 077-DIAA-JRJR-** 077-DIAA-KAKA-** 077-DIAA-KGKG-** 077-DIAA-KMKM-** 077-DIAA-KWKW-** 077-DIAA-LALA-** PQ - 120 Volts A. 120 Volts D. 240 Volts A. 125 Volts D.C. ...

Page 27

... Specify C.T. (Current Transformer) and V.T. (Voltage Transformer) ratios if used, and preferred scale at time of ordering ⁄ " Square Flange 1 2 Standard Case Catalogue No. 077-DW5A-QQ**-C6 077-DW5A-QS**-C6 077-DW8A-QQ**-C6 077-DW8A-QR**-C6 077-DW9A-QL**-C6 077-DW9A-QQ**-C6 077-DXLA-QQ**-C6 077-DXLA-QR**-C6 ⁄ Element, Transformer Rated 077-DXUA-QQ**-C6 077-DXUA-QR**-C6 077-DP5A-QQAD-C6 077-DP5A-QSAD-C6 077-DP7A-QQAD-C6 077-DP7A-QRAD-C6 077-DP7A-QSAD-C6 077-DP7A-QTAD-C6 ...

Page 28

Series ANSI Switchboard Meters LED Digital/Analogue Combination Scale – Options Options 1. Blank, uncalibrated dial (zero and full scale marks in pencil). 2. Red or coloured line or mark (specify position). 3. Coloured zones or segments (specify limits and ...

Page 29

... LED Synchroscope. 58 Fig. 3 Model 077-131 360° deg Dynamometer Power Factor Indicator 3 Phase Wire Balanced Load (3 Currents 1 Voltage). Fig. 6 Models 077-136, 077-136A, 078-136J 360° Dynamometer Power factor Indicator 3 Phase Wire Unbalanced Load. Fig. 9 Models 077-14D, 077-14G, 077-14H, 077-14L 360° ...

Page 30

... Fig. 17 Models 077-45R, 078-45R Temperature Indicator for Resistance Temperature Detector (RTD). 59 Fig. 12 Model 077-TFU Power Factor Meter 3 Phase 3 Wire Unbalanced Load. Fig. 15 Models 075-427, 077-427 078-427J, 079-427 Electronic Phase Angle Meter 3 phase wire Balanced Load. Fig. 18 Model 077-45T Temperature Indicator for Thermocouple Detector. ...

Page 31

... Wattmeter 3 Phase 3 Wire Balanced Load. Fig. 27 Model 077-21D Wattmeter 3 Phase 4 Wire Balanced Load. 60 Fig. 22 Model 078-215B, 078-KHBB Wattmeter Single Phase. Fig. 25 Models 077-218, 077-KHE 078-218J, 078-KHEJ, 079-218 Wattmeter 3 Phase 3 Wire Unbalanced Load. Fig. 28 Models 077-219, 077-KHG 078-219J, 078-KHGJ, 079-219 Wattmeter 3 Phase 4 Wire Unbalanced Load. ...

Page 32

... Series ANSI Switchboard Meters Connection Diagrams Fig. 29 Models 078-219B, 078-KHGB Wattmeter 3 Phase 4 Wire Unbalanced Load. Fig. 32 Models 077-31L, 078-31LJ Varmeter 3 Phase 3 Wire Unbalanced Load. Fig. 35 Models 077-31U, 077-KXG 078-31U, 079-31U Varmeter 3 Phase 4 Wire Unbalanced Load. Fig. 30 Models 077-21B Wattmeter 3 Phase 3 Wire Balanced Load 2 Reverse Connected CTs ...

Page 33

... LED Digital/Analogue Frequency Meter. Fig. 39 Model 077-DW9 LED Digital/Analogue Wattmeter 3 Phase 4 Wire Unbalanced Load. Fig. 42 Model 077-DP5 LED Digital/Analogue Phase Angle Meter Single Phase. Fig. 45 Models 077-DI2, 077-DIA 077-DIB, 077-DIC, 077-DIN, 077-DIT 077-DIV, 077-DIW LED Digital/Analogue Meter. 62 Fig. 40 Model 077-DXL LED Digital/Analogue Varmeter 3 Phase 3 Wire Unbalanced Load ...

Related keywords