1375967-4 TE Connectivity, 1375967-4 Datasheet - Page 5

BOARD-BOARD CONN RECEPTACLE 120WAY, 4ROW

1375967-4

Manufacturer Part Number
1375967-4
Description
BOARD-BOARD CONN RECEPTACLE 120WAY, 4ROW
Manufacturer
TE Connectivity
Series
AMPMODU PC/104r
Datasheets

Specifications of 1375967-4

Pitch Spacing
2.54mm
No. Of Rows
4
No. Of Contacts
120
Gender
Receptacle
Contact Termination
Through Hole
Contact Plating
Gold
Contact Material
Phosphor Bronze
Rohs Compliant
Yes
Product Type
Non-Stackthrough
Keyed
No
Pcb Mount Style
Through Hole
Board Standoff
Without
Signal Contact Current (a)
3
Insulation Resistance (m?)
1,000
Dielectric Withstanding Voltage (v)
500
Termination Post Length (mm [in])
2.84 [0.112]
Number Of Positions
120
Number Of Loaded Positions
120
Centerline (mm [in])
2.00 [0.079]
Pcb Mount Retention Type
None
Contact Configuration
Non-Stackthrough
Contact Base Material
Phosphor Bronze
Contact Plating, Mating Area, Material
Gold
Housing Material
Nylon
Housing Color
Black
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C
Rohs/elv Compliance History
Always was RoHS compliant
Temperature Range (°c)
-55 – +105
Lead Free Status / Rohs Status
 Details

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1375967-4
Manufacturer:
TE
Quantity:
20 000
4.
4.1.
4.2.
4.3.
4.4.
Rev C
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form, fit or function are made to the product or manufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determined by development/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures
attributed to equipment, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to
confirm corrective action is required before resubmittal.
Quality Conformance Inspection
The applicable quality inspection plan shall specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing
and this specification.
Specimen Selection
Specimens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. All test groups shall each consist of a minimum of 5
specimens.
Test Sequence
Qualification inspection shall be verified by testing specimens as specified in Figure 2.
108-1956