794000-2 TE Connectivity, 794000-2 Datasheet - Page 5

no-image

794000-2

Manufacturer Part Number
794000-2
Description
CONTACT, SOCKET, 26-24AWG, SOLDER
Manufacturer
TE Connectivity
Series
MRr
Datasheets

Specifications of 794000-2

Contact Material
Phosphor Bronze
Contact Plating
Gold
Contact Termination
Solder
Wire Size (awg)
26-24
Cable Diameter Min
0.025"
Rohs Compliant
Yes
Contact Gender
Socket
Product Type
Contact
Strain Relief
With
Wire/cable Type
Discrete Wire
Termination Method To Wire/cable
Crimp
Pcb Mount Retention
Without
Contact - Rated Current (a)
9
Hot Pluggable
No
Operating Voltage Reference
AC
Operating Voltage (vac)
250
Wire/cable Size (awg)
24 – 26
Wire/cable Size (mm²)
0.12 – 0.2
Wire/cable Size (cma)
236.823 – 394.705
Profile Height (y-axis) (mm [in])
1.94 [0.076]
Length (x-axis) (mm [in])
16.76 [0.6598]
Width (z-axis) (mm [in])
1.94 [0.076]
Contact Type
Socket
Contact Base Material
Phosphor Bronze
Contact Plating, Mating Area, Material
Gold
Contact Plating, Mating Area, Thickness (µm [?in])
0.76 [29.92]
Contact Design
Formed Socket
Mating Alignment
Without
Ul Voltage Rating (vac)
250
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Operating Temperature (°c [°f])
-55 – +105 [-67 – +221]
Applies To
Wire/Cable
Accepts Wire Insulation Diameter, Range (mm [in])
0.635 – 1.27 [0.025 – 0.050]
Application Use
Wire-to-Board, Wire-to-Board / Wire-to-Wire, Wire-to-Wire
Contact Transmits (typical Application)
Signal (Data)/ Power
Packaging Method
Reel
For Use With
MR Miniature Rectangular Connectors
4.2.
If changes significantly affecting form, fit or function are made to the product or manufacturing process, product
assurance shall coordinate requalification testing, consisting of all or part of the original testing sequence as
determined by development/product, quality and reliability engineering.
4.3.
Acceptance is based on verification that the product meets the requirements of Figure 1. Failures attributed to
equipment, test setup or operator deficiencies shall not disqualify the product. When product failure occurs,
corrective action shall be taken and samples resubmitted for qualification. Testing to confirm corrective action is
required before resubmittal.
4.4.
Applicable AMP quality inspection plan will specify the sampling acceptable quality level to be used.
Dimensional and functional requirements shall be in accordance with the applicable product drawing and this
specification.
Rev G
NOTE
Requalification Testing
Acceptance
Quality Conformance Inspection
(a)
(b)
A 1 foot minimum length of continuous lead for heat dissipation.
Termination resistance equals millivolts divided by test current less resistance of 6
inches of wire.
Termination Resistance Measurement Points
Figure 3
108-1022
5 of 7

Related parts for 794000-2