M49470X01106KAN AVX Corporation, M49470X01106KAN Datasheet - Page 14

CAPACITOR CERAMIC, 10UF, 50V, X7R, DIP

M49470X01106KAN

Manufacturer Part Number
M49470X01106KAN
Description
CAPACITOR CERAMIC, 10UF, 50V, X7R, DIP
Manufacturer
AVX Corporation
Datasheet

Specifications of M49470X01106KAN

Dielectric Characteristic
X7R
Capacitance
10µF
Capacitance Tolerance
± 10%
Voltage Rating
50VDC
Capacitor Case Style
DIP
No. Of Pins
8
Capacitor Mounting
Through Hole
Lead Spacing
10.2mm
Rohs Compliant
No
SMPS Stacked MLC Capacitors
(SM Style) DSCC #87106 and #88011
1/ Post checks are required (see paragraph 3.9 of MIL-PRF-49470).
2/ Marking defects are based on visual examination only. Any subsequent electrical defects shall not
1/ Unless otherwise specified herein, when necessary, mounting of group B samples shall be at the
2/ A sample unit having one or more defects shall be charged as a single defective.
3/ Order of tests is at discretion of manufacturer.
4/ See 3.2.3 of DSCC 87106.
5/ Sample size shall be 3 pieces with zero defectives permitted.
6/ Total of one defect allowed for combination of subgroup 1, subgroup 2, and subgroup 3 inspections.
Subgroup 1
Thermal shock and voltage conditioning 1/
Subgroup 2
Visual and mechanical examination:
Interface requirements
Marking 2/
Workmanship
Subgroup 1 3/
Temperature coefficient
Resistance to solvents 5/ 6/
Immersion
Terminal strength 5/
Subgroup 2
Resistance to soldering heat
Moisture resistance
Subgroup 3
Marking legibility
(laser marking only)
Subgroup 4
Solderability
Subgroup 5
Life
be used as a basis for determining marking defects.
discretion of the manufacturer.
Material
Physical dimensions
(other than physical dimensions)
Inspection
Inspection
MIL-PRF-49470
paragraph of
Requirement
3.28.1
Table III. Group B inspection. 1/
3.23
3.18
3.24
3.20
3.21
3.15
3.26
Table II. Group A inspection.
4/
MIL-PRF-49470
paragraph of
Requirement
3.5 and 3.5.1
3.28
3.30
3.9
3.4
3.1
MIL-PRF-49470
paragraph of
Test method
4.8.4.1
4.8.20
4.8.15
4.8.10
4.8.17
4.8.18
4.8.12
4.8.22
4/
MIL-PRF-49470
paragraph of
Test method
4.8.5
4.8.4
to be inspected
sample units
Number of
per case code
5 minimum
12
12
6
3
Sampling procedure
100% inspection
13 samples
1
1
1
permitted 2/
0 failures
Number of
defectives
0
0
6/ 1
21

Related parts for M49470X01106KAN