HMR2300-D20-232 Honeywell, HMR2300-D20-232 Datasheet
HMR2300-D20-232
Specifications of HMR2300-D20-232
Related parts for HMR2300-D20-232
HMR2300-D20-232 Summary of contents
Page 1
... PCB or Aluminum Enclosure Options • 6-15 volt DC Unregulated Power Supply Interface General Description The Honeywell HMR2300 is a three-axis smart digital magnetometer to detect the strength and direction of an incident magnetic field. The three of Honeywell’s magneto-resistive sensors are oriented in orthogonal directions to measure the X, Y and Z vector components of a magnetic field ...
Page 2
... HMR2300 SPECIFICATIONS Characteristics Power Supply Supply Voltage Pin 9 referenced to Pin 5 (Ground) Supply Current Vsupply = 15V, with S Temperature Operating Storage Magnetic Field Range Full Scale (FS), Total Field Applied Resolution Applied Field to Change Output Accuracy RSS of All Errors @+25°C Linearity Error Best Fit Straight Line @+25°C 3 Sweeps Across ± ...
Page 3
... HMR2300 Characteristics Digital I/O Timing (See Timing Diagrams) T *dd Commands (dd = Device ID) RESP T *dd Commands (dd = Device ID) DELAY T BYTE T Power Applied to End of Start-Up STARTUP RS-232 COMMUNICATIONS – Figure1 (Timing is Not to Scale) RS-485 COMMUNICATIONS – Figure 2 (Timing is Not to Scale) Solid State Electronics Center • www.magneticsensors.com • (800) 323-8295 • Page 3 ...
Page 4
... HMR2300 GLOBAL ADDRESS (*99) DELAY – Figure 3 (Timing is Not to Scale) PIN CONFIGURATION Pin Number PCB DIMENSIONS AND PINOUT – Figure 4 (Connector Not Shown for Clarity) Solid State Electronics Center • www.magneticsensors.com • (800) 323-8295 • Page 4 Pin Name NC No Connection TD Transmit Data, RS-485 (B+) ...
Page 5
... HMR2300 CASE DIMENSIONS – Figure 5 RS-232 UNBALANCED I/O INTERCONNECTS – Figure 6 HOST PC HOST Solid State Electronics Center • www.magneticsensors.com • (800) 323-8295 • Page SENSOR PRODUCTS HMR2300 HMR2300 ...
Page 6
... HMR2300 receive (RD) data line, and the other is from the HMR2300 TD to the PC RD data line. When a logic one is sent, either the line will drive to about +6 Volts referenced to ground. For a logic zero, the line will drive to about –6 Volts below ground. Since the signals are transmitted and dependent on an absolute voltage level, this limits the distance of transmission due to line noise and signal to about 60 feet ...
Page 7
... HMR2300 COMMAND INPUTS A simple command set is used to communicate with the HMR2300. These commands can be automated; or typed in real-time while running communication software programs, such a windows hyperterminal. Command Inputs (1) Format *ddWE *ddA *ddWE *ddB Output *ddP *ddC Esc Sample Rate *ddWE *ddR=nnn Set/Reset ...
Page 8
... HMR2300 DATA FORMATS The HMR2300 transmits each X, Y, and Z axis as a 16-bit value. The output data format can be either 16-bit signed binary (sign plus 15 bits binary coded decimal (BCD) ASCII characters. The command *ddA will select the ASCII format and *ddB will select the binary format. ...
Page 9
... To turn off the internal switching, enter the command *ddTF or *ddT. In this state the sensors are either in a Set or Reset mode. If the HMR2300 is exposed to a large magnetic field (>10 gauss), then another set pulse is required to maximize output sensitivity. ...
Page 10
... Table for each sample rate. The default rate of 20 sps has a bandwidth of 17Hz. The digital filter inside the HMR2300 is the combination of a comb filter and a low pass filter. This provides a linear phase response with a transfer function that has zeros in it. ...
Page 11
... The HMR2200 Smart Digital Magnetometer contains all the basic sensors and electronics to provide digital indication of magnetic field strength and direction. The HMR2300 has all three axis of magnetic sensors on the far end of the printed circuit board, away from the J1 and J2 connector interfaces. The HMR2300 uses the circuit board mounting holes or the enclosure surfaces as the reference mechanical directions ...
Page 12
... HMR2300-D20-232 HMR2300-D20-485 HMR2300-D21-232 HMR2300-D21-485 HMR2300-D20-232-DEMO HMR2300-D21-232-DEMO Honeywell reserves the right to make changes to improve reliability, function or design. Honeywell does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights nor the rights of others. ...