E2EX3D1N Omron, E2EX3D1N Datasheet - Page 40

E2EX3D1N

Manufacturer Part Number
E2EX3D1N
Description
Manufacturer
Omron
Datasheet

Specifications of E2EX3D1N

Proximity Sensor Type
Inductive
Output Type
NPN/PNP
Proximity Sensor Sensing Distance
3mm
Proximity Sensor Sensing Distance Range
2 to 7mm
Proximity Sensor Switching Mode
NO
Mounting
Panel
Operating Temp Range
-25C to 70C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
10V
Operating Supply Voltage (typ)
12/15/18/24V
Operating Supply Voltage (max)
30V
Pin Count
4
Lead Free Status / Rohs Status
Compliant
Pre-wired Models
(Shielded)
40
Fig. 1: E2E-CR6@@
Fig. 2: E2E-CR8@@
Pre-wired Models
(Shielded)
Fig. 5: E2E-X2D@-N
Fig. 7: E2E-X1R5Y@
Fig. 9: E2E-X3D@-N
Note: D Models:
Note: D Models: Operation indicator (red),
3±0.1 dia.
21 dia.
15 dia.
4 dia.
15 dia.
17
13
Operation indicator (red),
setting indicator (green);
E, F Models:
Operation indicator (red)
setting indicator (green);
E, F Models: Operation indicator (red)
13
E2E-X1R5E@/F@
E2E-X2E@/F@
M12 × 1
M8 × 1
M8 × 1
E2E/E2E2
Toothed
washer
Toothed washer
17
3
4
17.5
Toothed
washer
3
Operation
indicator
(red)
27
33
25
26
Operation
indicator
(red)
38
Two
clamping nuts
30
Two
clamping nuts
Two clamping
nuts
36
Operation Indicator (red)
40
Indicator
(See note.)
8
Indicator
(See note.)
10
2.4-dia. (7/0.127-dia.) vinyl-insulated round cable
with 3 conductors,
Standard length: 2 m
2.9-dia. vinyl-insulated round cable with
3 conductors (Conductor cross section: 0.14 mm
Insulator diameter: 0.9 mm),
Standard length: 2 m
Robotics cable Models: 2.9-dia. vinyl-insulated
round cable with 3 conductors (Conductor cross
section: 0.15 mm
Standard length: 2 m
The cable can be extended up to 100 m (separate
metal conduit).
8
7
9
Cylindrical Proximity Sensor
7
4-dia. vinyl-insulated round cable with
2 conductors (D Models)/3 conductors
(D@S,E, F Models) (Conductor cross section:
0.3 mm
Standard length: 2 m
Robotics cable Models: 4-dia.
vinyl-insulated round cable with 2 conductors
(D Models)/3 conductors (E Models)
(Conductor cross section: 0.3 mm
diameter: 1.27 mm),
Standard length: 2 m
The cable can be extended (separate metal conduit)
up to 200 m (control output) or up to 100 m
(diagnostic output).
4-dia. vinyl-insulated round cable with
2 conductors (D Models)/3 conductors
(E, F Models)(Conductor cross section:
0.3 mm
Standard length: 2 m
Robotics cable Models: 4-dia.
vinyl-insulated round cable with
2 conductors (D Models)/3 conductors
(E Models)(Conductor cross section:
0.3 mm
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
0.3 mm
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
Pre-wired e-CON connector Model
Connector:
Product code 37104-3163-000FL
(Sumitomo 3M)
2
,Insulator diameter: 1.3 mm),
2
2
2
, Insulator diameter: 1.05 mm),
, Insulator diameter: 1.3 mm),
, Insulator diameter: 1.27 mm),
2
, Insulator diameter: 1.3 mm),
15.6
1
2
3
4
2
, Insulator
5.9
15
2
,
Pre-wired Models
(Unshielded)
Fig. 6: E2E-X4MD@
Fig. 8: E2E-X2MY@
Fig. 10: E2E-X8MD@
Fig. 3: E2E-C1@@
Fig. 4: E2E-X1@@
5.4 dia.
15 dia.
9.7 dia.
Note: D Models: Operation indicator (red),
15 dia.
21 dia.
13
13
17
8
Note: D Models:
setting indicator (green);
E, F Models: Operation indicator (red)
E2E-X2ME@/F@
6.1 dia.
M5 × 0.5
E2E-X5ME@/F@
6.1 dia.
9 dia.
Operation indicator (red),
setting indicator (green);
E, F Models:
Operation indicator (red)
M8 × 1
Operation
indicator
(red)
M12 × 1
M8 × 1
6
6
Toothed
washer
17.5
7
Toothed
washer
4
17.5
3
15
25
3
26
Toothed
washer
25
36
Toothed
washer
33
4
2.9-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.14 mm
Standard length: 2 m
Robotics cable Models: 2.9-dia. vinyl-insulated round cable with
3 conductors (Conductor cross section: 0.15 mm
Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
Two
clamping nuts
40
30
38
Two
clamping nuts
Two clamping nuts
8
Two
clamping nuts
Operation
indicator (red)
Indicator
(See note.)
8
Operation
indicator (red)
10
Indicator
(See note.)
7
7
9
4-dia. vinyl-insulated round cable with
2 conductors (D Models)/3 conductors
(D@S, E, F Models) (Conductor cross section:
0.3 mm
Standard length: 2 m
Robotics cable models: 4-dia.
vinyl-insulated round cable with 2 conductors
(D Models)/3 conductors (E Models)
(Conductor cross section: 0.3 mm
diameter: 1.27 mm),
Standard length: 2 m
The cable can be extended (separate metal
conduit) up to 200 m (control output) or up to
100 m (diagnostic output).
4-dia. vinyl-insulated round cable with
2 conductors (D Models)/3 conductors (E, F
Models)(Conductor cross section: 0.3 mm
Insulator diameter: 1.3 mm),
Standard length: 2 m
Robotics cable models: 4-dia.
vinyl-insulated round cable with
2 conductors (D Models)/3 conductors (E
Models)(Conductor cross section:
0.3 mm
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
4-dia. vinyl-insulated round cable with
2 conductors (Conductor cross section:
0.3 mm
Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
Pre-wired e-CON connector Model
2
, Insulator diameter: 1.3 mm),
2
, Insulator diameter: 1.27 mm),
2
, Insulator diameter: 1.3 mm),
2.9-dia. vinyl-insulated round cable
with 3 conductors
(Conductor cross section: 0.14 mm
Insulator diameter: 0.9 mm),
Standard length: 2 m
Robotics cable Models: 2.9-dia.
vinyl-insulated round cable with
3 conductors (Conductor cross
section: 0.15 mm
diameter: 1.05 mm),
Standard length: 2 m
The cable can be extended up to
100 m (separate metal conduit).
Connector:
Product code 37104-3163-000FL
(Sumitomo 3M)
2
, Insulator diameter: 0.9 mm),
15.6
2
, Insulator
2
,
2
1
2
3
4
, Insulator
5.9
15
2
,
2
,

Related parts for E2EX3D1N