D4GSN1R5 Omron, D4GSN1R5 Datasheet - Page 3

no-image

D4GSN1R5

Manufacturer Part Number
D4GSN1R5
Description
Manufacturer
Omron
Type
Safety-Door Switchr
Datasheet

Specifications of D4GSN1R5

Switch Function Configuration
N.O./N.C.
Current Rating (max)
0.75A
Operating Temp Range
-30C to 70C
Lead Free Status / Rohs Status
Compliant
Characteristics
Note: 1. The above values are initial values.
*1. The degree of protection shown above is based on the test method specified in EN60947-5-1. Be sure to confirm in advance the sealing
*2. The durability conditions are an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your
*3. When the ambient temperature is 35°C or higher, do not apply 1 A at 125 VAC to more than one circuit.
*4. These figures are minimum requirements for safe operation.
*5. The value given for minimum applicable load is a reference value for microloads. The value will vary depending on factors such as the switching
Degree of protection *1
Durability *2
Operating speed
Operating frequency
Direct opening force *4
Direct opening travel *4
Contact resistance
Minimum applicable load *5
Rated insulation voltage (U
Rated frequency
Protection against electric shock
Pollution degree (operating environment)
Impulse withstand
voltage
(EN60947-5-1)
Insulation resistance
Contact gap
Vibration resistance
Shock resistance
Conditional short-circuit current
Conventional free air thermal current (I
Ambient operating temperature
Ambient operating humidity
Cable
Weight
performance under the actual operating environment and conditions.
Although the switch box is protected from dust, oil, or water penetration, do not use the D4GS-N in places where dust, oil, water, or chemicals
may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
OMRON representative.
frequency, the ambient environment, and the reliability level. Be sure to confirm correct operation with the actual load before application.
2. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however,
they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability
for smaller loads may be reduced.
Mechanical
Electrical
Between terminals of
same polarity
Between terminals of
different polarity
Between each
terminal and
non-current carrying
metallic parts
Malfunction
Destruction
Malfunction
i
)
th
)
IP67 (EN60947-5-1)
1,000,000 operations min.
100,000 operations min. (1 A resistive load at 125 VAC) *3
0.1 to 0.5 m/s
30 operations/minute max.
60 N min.
10 mm min.
300 mΩ max. (with 1 m cable)
Resistive load of 4 mA at 24 VDC (N-level reference value)
250 V
50/60 Hz
Class II (double insulation) (IEC60536)
3 (EN60947-5-1)
2.5 kV
4 kV
6 kV
100 MΩ min. (at 500 VDC) between terminals of the same polarities, between terminals of
different polarities, and between each terminal and non-current carrying metal parts
2 × 2 mm min.
10 to 55 Hz, 0.35 mm single amplitude
1,000 m/s
300 m/s
100 A (EN60947-5-1)
2.5 A (EN60947-5-1)
−30 to 70°C (with no icing)
95% max.
UL2464 No. 22 AWG, finishing O.D.: 7.2 mm
Approx. 120 g (D4GS-N1R, with 1 m cable)
2
min.
2
min.
D4GS-N
3