SC4150HIS4TRT Semtech, SC4150HIS4TRT Datasheet

no-image

SC4150HIS4TRT

Manufacturer Part Number
SC4150HIS4TRT
Description
Manufacturer
Semtech
Datasheet

Specifications of SC4150HIS4TRT

Linear Misc Type
Negative Voltage
Family Name
SC4150
Package Type
SOIC
Operating Supply Voltage (min)
-10V
Operating Supply Voltage (max)
-80V
Operating Temperature (min)
-40C
Operating Temperature (max)
125C
Operating Temperature Classification
Automotive
Product Depth (mm)
4mm
Product Height (mm)
1.5mm
Product Length (mm)
5mm
Mounting
Surface Mount
Pin Count
8
Lead Free Status / Rohs Status
Compliant
The SC4150 is a negative voltage hotswap controller that
allows the insertion of line cards into a live backplane.
The inrush current is programmable and closed loop op-
eration limits the maximum current even under short cir-
cuit conditions. A built in timing circuit prevents false shut-
down. The signal from the drain voltage is fed to the
timer, providing safety for the MOSFET when in linear
mode. The SC4150 latches off under abnormal condi-
tion and attempts to restart after a time out period.
The device comes in two options, PWRGD (SC4150H)
and PWRGD (SC4150L). These signals can be directly
used to enable power modules.
Revision: April 14, 2004
POWER MANAGEMENT
Description
Typical Application Circuit
PWRGD/PWRGD
GND(remote)
GND
-- 48V
562k
9.31k
10.2k
R1
R2
R3
0.001
C2
1
2
3
4
PWRGD
OV
UV
VEE
/PWRGD
SC4150
U1
R4
0.01
Figure 1
DRAIN
SENSE
GATE
VCC
1
Features
Applications
8
7
6
5
Programmable slew of the inrush current when
used for hot insertion in the negative 24V and 48V
backplane
Closed loop operation limits the maximum current
even in short circuit condition
Built in timer prevents false shutdown, when the
closed loop operation limits the current.
Sensing the drain voltage allows for immediate
shutdown in short circuit condition, where current
spikes and noise is ignored.
Power good signal
Input UVLO and OVLO sensing
SO-8 package
Central office switching
-48V Distributed power systems
Power supply hotswap & inrush control
C3
0.33
Vee
VEE
R5
10
0.1
C1
R6
18k
Q1
Hot Swap Controller
C4
3.3nF
Negative Voltage
150
C5
www.semtech.com
SC4150

Related parts for SC4150HIS4TRT

SC4150HIS4TRT Summary of contents

Page 1

... Central office switching -48V Distributed power systems Power supply hotswap & inrush control U1 SC4150 1 8 PWRGD /PWRGD VCC DRAIN GATE 4 5 VEE SENSE C2 C3 0.001 0.33 R4 0.01 Figure 1 1 SC4150 Negative Voltage Hot Swap Controller C1 0.1 Vee VEE C4 R6 18k 3.3nF C5 150 www.semtech.com ...

Page 2

... Exceeding the specifications below may result in permanent damage to the device, or device malfunction. Operation outside of the parameters specified in the Electrical Characteristics section is not implied Electrical Characteristics Unless specified 25° 48V Values in bold apply over full operating temperature range 2004 Semtech Corp 0V SC4150 ...

Page 3

... POWER MANAGEMENT Electrical Characteristics (Cont.) Unless specified 25° 48V Values in bold apply over full operating temperature range Note: (1) This device is ESD sensitive. Use of standard ESD handling precaution is required. 2004 Semtech Corp > < SC4150 www.semtech.com µ µ µ A µ s µ s µ s µ ...

Page 4

... POWER MANAGEMENT Pin Configuration TOP VIEW PWRGD/PWRGD VEE 4 (SO-8) Pin Descriptions 2004 Semtech Corp. Ordering Information VCC DRAIN GATE Notes: (1) Only available in tape and reel packaging. A reel 5 SENSE contains 2500 devices. (2) Device marking: SC4150H, SC4150L - 100ms 4150H-4, 4150L-4 - 400ms (3) Lead free product ...

Page 5

... Block Diagram Active High PWRGD Vcc 12.5V Reg 60mV + Vee SENSE Active Low PWRGD Vcc 12.5V Reg 60mV + Vee SENSE 2004 Semtech Corp. 1.223V 50uA Timer _ +7V + Delay GATE DRAIN 1.223V 50uA Timer _ +7V + Delay GATE DRAIN 5 SC4150 PWRGD _ + 1.75V PWRGD _ + 1.75V ...

Page 6

... C1 R3 60mV Vee R4 -48V 2004 Semtech Corp. Resistors R1, R2 and R3 make up a voltage divider to set the Under-Voltage (UV) and Over-Voltage (OV) trip points. When the input power supply ramps up the UV trips at 1.273V and OV trips at 1.223V; during the ramp down transition the UV trips at 1.223V and OV trips at 1.198V. ...

Page 7

... Vmax /Imax = 150µF · 70V / 3A = 3.5ms This would be the minimum time for the gate voltage plateau during which the Vdd linearly decreases maintaining 3A charge current of the Cload. 2004 Semtech Corp. The inrush can be calculated using the following equation (50 µA • C ...

Page 8

... Below are the snap-shots taken at start-up with different loading conditions and during the application of the over- current at the output of the circuit. For all figures, Ch1 Ch2: V DRAIN Figure 3. Start-up with no load. Figure 5. Start-up with 1Amp load. 2004 Semtech Corp. ; Ch3: PWRGD; Ch4: V (Input current) GATE R4 Figure 6. From 3A load into “short circuit”. 8 SC4150 Figure 4 ...

Page 9

... For all figures, Ch1 Ch2: V DRAIN Figure 7. Short circuit hiccup. Figure 9. Inrush limit. 2004 Semtech Corp. ; Ch3: PWRGD (referenced to V GATE 9 SC4150 ); Ch4: V (Input current) ...

Page 10

... POWER MANAGEMENT Evaluation Board Schematic GND GND(remote) C1 0.1 R1 562k R2 9.31k C2(opt) R3 0.01 10.2k -- 48V Evaluation Board 2004 Semtech Corp. U1 SC4150H PWRGD/PWR AIN C4 R6 18k 3.3nF GATE 4 5 VEE SENSE 0. 0.01 IRF1310 10 SC4150 R7 Copt (opt) 0.1 ON/OFF +Vout +Vin C6(opt) POWER C5 150 ...

Page 11

... POWER MANAGEMENT Evaluation Board - Bill of Materials 2004 Semtech Corp SC4150 www.semtech.com ...

Page 12

... POWER MANAGEMENT Outline Drawing - SO-8 Minimum Land Pattern - SO-8 Contact Information Phone: (805)498-2111 FAX (805)498-3804 2004 Semtech Corp. Semtech Corporation Power Management Products Division 200 Flynn Road, Camarillo, CA 93012 12 SC4150 JEDEC REF: MS-012AA www.semtech.com ...

Related keywords