PVU414 International Rectifier, PVU414 Datasheet - Page 2

no-image

PVU414

Manufacturer Part Number
PVU414
Description
Manufacturer
International Rectifier
Datasheet

Specifications of PVU414

Input Type
DC
Output Type
AC/DC
Output Voltage (max)
400V
Input Current (max)
25mA
Output Current
140@Ta=40CmA
Isolation Voltage
4kV
Circuit Arrangement
1 Form A
Package Type
PDIP
Output Device
MOSFET
Pin Count
6
Mounting
Through Hole
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Rad Hardened
No
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PVU414
Manufacturer:
IR
Quantity:
20 000
Part Number:
PVU414S
Manufacturer:
IR
Quantity:
20 000
Part Number:
PVU414SPBF
Manufacturer:
Mini-Circ
Quantity:
2 300
Part Number:
PVU414SPBF
Manufacturer:
IR
Quantity:
20 000
Electrical Specifications (-40°C ≤ T
OUTPUT CHARACTERISTICS
GENERAL CHARACTERISTICS
www.irf.com
International Rectifier does not recommend the use of this product in aerospace, avionics, military or life support applications.
Users of this International Rectifier product in such applications assume all risks of such use and indemnify International
Rectifier against all damages resulting from such use.
INPUT CHARACTERISTICS
Minimum Control Current (see figure 1)
Maximum Control Current for Off-State Resistance @T
Control Current Range (Caution: current limit input LED, see figure 6)
Maximum Reverse Voltage
Operating Voltage Range
Maximum Load Current @T
Maximum On-State Resistance @T
Minimum Off-State Resistance @T
Maximum Turn-On Time @T
Maximum Turn-Off Time @T
Maximum Thermal Offset Voltage @ 5mA Control
Maximum Output Capacitance @ 50V
Minimum Dielectric Strength, Input-Output
Minimum Insulation Resistance, Input-Output @T
Maximum Capacitance, Input-Output
Maximum Pin Soldering Temperature (10 seconds maximum)
Ambient Temperature Range:
For 50mA pulsed load, 5mA Control (see figure 4)
For 50mA, 100 V
For 50mA, 100 V
DC
DC
A Connection
B Connection
C Connection
A Connection
B Connection
C Connection
Load, 5mA Control
Load, 5m
A
A
A
=+40°C, 5mA Control (See figure 1)
A
Control
=+25°C (see figure 7)
=+25°C (see figure 7)
A
A
=+25°C, ±320V (see figure 5)
=+25°C
DC
(see figure 2)
A
≤ +85°C unless otherwise specified)
A
=+25°C, 50%RH, 100V
A
=+25°C
Operating
Storage
DC
-40 to +100
-40 to +85
0 to ±400
3.0 to 25
Limits
Limits
Limits
4000
+260
10
10
140
150
210
500
200
3.0
0.4
6.0
0.2
1.0
27
14
12
Series PVU414PbF
7
10
12
V(DC or AC peak)
mA (AC or DC)
mA (DC)
mA (DC)
Units
Units
Units
V
mA
mA
mA
µV
pF
pF
µs
µs
°C
°C
V
RMS
2

Related parts for PVU414