OPI120 Optek Technology (TT electronics), OPI120 Datasheet - Page 3

no-image

OPI120

Manufacturer Part Number
OPI120
Description
Manufacturer
Optek Technology (TT electronics)
Datasheet

Specifications of OPI120

Input Type
DC
Output Type
DC
Output Device
Transistor
Number Of Elements
1
Reverse Breakdown Voltage
3V
Forward Voltage
1.5V
Forward Current
150mA
Collector-emitter Voltage
25V
Power Dissipation
250mW
Collector-emitter Saturation Voltage
0.5V
Current Transfer Ratio
70%
Pin Count
5
Mounting
Through Hole
Operating Temp Range
-55C to 100C
Operating Temperature Classification
Industrial
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
OPI120
Manufacturer:
OPT
Quantity:
15
Part Number:
OPI1203-3
Quantity:
5 510
Part Number:
OPI1203-3
Quantity:
5 510
Optically Coupled Isolator
OPI120, OPI123
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
Electrical Characteristics
Input Diode
Output Photosensor (See OP236 for additional information - for reference only)
Coupled (See OP804 and OP805 for additional information - for reference only)
SYMBOL
V
V
V
Notes:
(1) Measured with input and output leads shorted in air with a maximum relative humidity of 50%.
V
I
I
(BR)CEO
(BR)ECO
(BR)CBO
CB(ON)
CE(SAT)
V
I
I
C(ON)
t
V
CEO
C/
r
I
, t
ISO
R
F
I
F
f
If suitably encapsulated or oil-immersed, the isolation voltage is increased to 25 kV minimum.
Forward Voltage
Reverse Current
Collector-Emitter Breakdown Voltage
Emitter-Collector Breakdown Voltage
Collector-Base Breakdown Voltage
Collector-Emitter Dark Current
DC Current Transfer Ratio
Collector Saturation Voltage
On Collector Current
On Collector Base Current—OPI120
Isolation Voltage
Output Rise Time, Output Fall Time
OPI120
OPI123
OPI120
OPI123
OPI120
OPI120
OPI123
OPI120
OPI123
OPI120
OP123
OPI120
OPI123
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
I = 10 mA
F
PARAMETER
Vcc
(1)
R = 200 Ohms
(
OPI120
-40
FAX: (972) 323-2396 sensors@optekinc.com www.optekinc.com
o
C to +85° C unless otherwise noted)
Vcc
R = 50 Ohms
Vout
MIN
2.0
5.0
25
20
25
20
50
15
15
5
-
-
-
-
-
-
-
-
Test Circuit
TYP
70
40
2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
I = 10 mA
F
MAX
100
100
1.5
1.5
0.5
1.2
50
-
-
-
-
-
-
-
-
-
-
-
Vcc
R = 200 Ohms
UNITS
mA
µA
nA
µA
kV
µs
%
V
V
V
V
V
I
I
V
I
I
I
I
V
I
I
I
I
I
I
I
See note 1
See Test Circuit
OPI123
F
F
C
C
E
C
F
F
F
F
F
F
F
R
CE
= 30 mA
= 10 mA
= 10 mA, V
= 10 mA, V
= 30 mA, I
= 5 mA, I
= 10 mA, V
= 10 mA, V
= 30 mA, V
= 1 mA
= 1 mA
= 100 µA
= 1 mA
= 3 V
= 10 V
Vcc
TEST CONDITIONS
C
C
= 1 mA
CE
CE
CE
CE
CB
= 1 mA
R = 50 Ohms
= 5 V
= 2 V
= 5 V
= 2 V
= 5 V
Vout
Issue A .2
Page 3 of 3
04/08

Related parts for OPI120