3.
The Intel
variations may be chosen for future board sets to satisfy the system power, power distribution,
thermal performance, acoustic noise, and cost requirements.
The typical PS/2 form factor power supply with a remote enable feature can be used. The remote
enable feature permits the system power to be activated from a variety of sources, allowing the
implementation of Wake on LAN (WOL) or other remote management features. The 450-W Entry
Power Supply (EPS) features Entry SSI (Rev. 3.0)-compliant server board connectors and is
positioned as the entry power supply solution for the Intel
Refer to the 450-W EPS 1.0 Power Supply Specification for details (see Appendix B for order
number).
The Intel
supply. The 650-W power supply features three removable modules inserted into a main housing
(or cage). The main housing contains dual AC input circuits and power distribution boards. The
standard configuration ships with two 350-W TPS modules and one baffle installed for non-
redundant operation. Three 350-W TPS modules and both power cords must be installed for
redundant operation. The removable hot-swap DC power modules can be replaced in the event of
a failure. The system will remain in operation during a failed voltage condition and remain online
during a single module replacement for maximum up time. Refer to the 650-W 2+1 Redundant
Power Supply Cage Specification for details.
The following table is a brief overview of the system power.
Revision 1.0
Chassis Power Subsystem
®
®
SC5200 Server Chassis supports two different PFC power supply solutions. Additional
SHG2 Server Board system can also be configured with a 650-W, 2+1 redundant power
®
SHG2 and SE7500CW2 Server Boards.