ACS710KLATR-12CB-T Allegro, ACS710KLATR-12CB-T Datasheet

no-image

ACS710KLATR-12CB-T

Manufacturer Part Number
ACS710KLATR-12CB-T
Description
Manufacturer
Allegro
Datasheets

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACS710KLATR-12CB-T
Manufacturer:
IR
Quantity:
3 100
Part Number:
ACS710KLATR-12CB-T
Manufacturer:
ALLEGRO/雅丽高
Quantity:
20 000
Company:
Part Number:
ACS710KLATR-12CB-T
Quantity:
9 000
Features and Benefits
▪ Industry-leading noise performance with greatly
▪ Small footprint package suitable for space-constrained
▪ 1 mΩ primary conductor resistance for low power loss
▪ High isolation voltage, suitable for line-powered
▪ User-adjustable Overcurrent Fault level
▪ Overcurrent Fault signal typically responds to an
▪ Integrated shield virtually eliminates capacitive
▪ Filter pin capacitor improves resolution in low
▪ 3 to 5.5 V, single supply operation
▪ Factory trimmed sensitivity and quiescent output
▪ Chopper stabilization results in extremely stable
▪ Ratiometric output from supply voltage
Package: 16-pin SOIC Hall Effect IC
Package (suffix LA)
ACS710-DS
improved bandwidth through proprietary amplifier and
filter design techniques
applications
applications
overcurrent condition in < 2 μs
coupling from current conductor to die due to high
dV/dt voltage transients
bandwidth applications
voltage
quiescent output voltage
I
P
1
2
3
4
5
6
7
8
IP+
IP+
IP+
IP+
IP–
IP–
IP–
IP–
Current Sensor with Integrated Overcurrent Detection
ACS710
Approximate Scale 1:1
FAULT_EN
FILTER
FAULT
VIOUT
VZCR
GND
VOC
VCC
16
15
14
13
12
11
10
9
120 kHz Bandwidth, High Voltage Isolation
Fault_EN
V
IOUT
C
OC
1 nF
A
Typical Application
R
R
R
L
B
H
PU
C
V
F
CC
0.1 μF
Description
The Allegro
precise means for current sensing applications in industrial,
commercial, and communications systems. The device is offered
in a small footprint surface mount package that allows easy
implementation in customer applications.
The ACS710 consists of a precision linear Hall sensor integrated
circuit with a copper conduction path located near the surface
of the silicon die. Applied current flows through the copper
conduction path, and the analog output voltage from the Hall
sensor linearly tracks the magnetic field generated by the
applied current. The accuracy of the ACS710 is maximized
with this patented packaging configuration because the Hall
element is situated in extremely close proximity to the current
to be measured.
High level immunity to current conductor dV/dt and stray
electric fields, offered by Allegro proprietary integrated shield
technology, guarantees low ripple at output and low offset drift
in high-side, high voltage applications.
The voltage on the Overcurrent Input (VOC pin) allows
customers to define an overcurrent fault threshold for the
device. When the current flowing through the copper conduction
path (between the IP+ and IP– pins) exceeds this threshold,
Continued on the next page…
R
C
H
C
A
B
, R
OC
F
L
®
ACS710 current sensor provides economical and
Sets resistor divider reference for V
Noise and bandwidth limiting filter capacitor
Fault delay setting capacitor, 22 nF maximum
Use of capacitor required
Use of resistor optional, 330 kΩ recommended.
If used, resistor must be connected between
¯ F ¯ ¯ A ¯ U ¯ ¯ L ¯ ¯ T ¯ pin and V
CC
.
ACS710
OC

Related parts for ACS710KLATR-12CB-T

Related keywords