4-1123723-5 TE Connectivity, 4-1123723-5 Datasheet
4-1123723-5
Specifications of 4-1123723-5
Related parts for 4-1123723-5
4-1123723-5 Summary of contents
Page 1
... In the event of conflict between the requirements of this specification and the referenced documents, this specification shall take precedence. 2.1. Tyco Electronics Documents ! 114-13265: Application Specification (Economy Power II Contacts and Connectors) ! 501-TBD: Qualification Test Report (EP II Connector System) 2.2. Industry Document EIA-364: Electrical Connector/Socket Test Procedures Including Environmental Classifications 2 ...
Page 2
... Voltage: 600 volts AC ! Current: See Figure 4 for applicable current carrying capability. Maximum rated current that can be carried by this product is limited by maximum operating temperature of the housings (105° C) and temperature rise of the housings (30° C). Variab les to be considered for each application are: wire size, connector size, contact material, ambient temperature, and printed circuit board design ...
Page 3
... EIA-364-8. Determine crimp tensile at a rate of 25.4 mm per minute. EIA-364-29. Apply axial load at a rate of 4.4 N per second and hold for 6 seconds. EIA-364-32, Test Condition VII. Subject specimens to 10 cycles between -55 and 105° C with 30 minute dwells at temperature extremes ...
Page 4
... Random vibration Mechanical shock Durability Mating force Unmating force Crimp tensile Contact retention Thermal shock Humidity/temperature cycling Temperature life Final examination of product (a) See paragraph 4.1.A. NOTE (b) Numbers indicate sequence in which tests are performed. (c) Precondition specimens with 10 durability cycles. Rev O5 Test Group ( ...
Page 5
... If product failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to confirm corrective action is required before resubmittal. 4.4. Quality Conformance Inspection The applicable quality inspection plan shall specify the sampling acceptable quality level to be used. ...
Page 6
... To determine acceptable current carrying capacity for percentage connector loading and wire NOTE gage indicated, use the Multiplication Factor (F) from the above chart and multiply it times the Base rated Current for a single circuit at the maximum ambient operating temperature shown in Figure 4A. Rev O5 Figure 4A Current Carrying Capability ...