D38999/20WJ19PC Amphenol, D38999/20WJ19PC Datasheet - Page 203

Circular MIL / Spec Connectors 19P Sz 25 Wall Mount Receptacle OD Cad

D38999/20WJ19PC

Manufacturer Part Number
D38999/20WJ19PC
Description
Circular MIL / Spec Connectors 19P Sz 25 Wall Mount Receptacle OD Cad
Manufacturer
Amphenol
Series
38999 Seriesr
Datasheet

Specifications of D38999/20WJ19PC

Mil Type
MIL-DTL-38999 III
Product Type
Connectors
Contact Style
Pin (Male)
Shell Style
Receptacle
Shell Size
25
Number Of Contacts
19
Insert Arrangement
25-19
Mating Style
Self Locking
Mounting Style
Wall
Termination Style
Crimp
Contact Type
Pin
Shell Plating
Cadmium, Olive Drab
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
TVP00RW2519PC
202
Contact Amphenol Aerospace for more information at 800-678-0141 • www.amphenol-aerospace.com
Amphenol
Ozone Exposure (Classes E, G, R & K)
Insert Retention (Classes E, G, R & K)
Air Leakage (Classes E, G, R & K)
Ground Resistance (Class G)
Flame Resistance (Class K)
TEST REQUIREMENTS
Contact Insertion Force
Thermal Shock (Mated)
Sand & Dust Exposure
Magnetic Permeability
(Classes E, G, R & K)
Insulation Resistance
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
(Classes E, G, R & K)
Moisture Resistance
Altitude Immersion
Contact Retention
Low Temperature
Fluid Resistance
Temperature Life
Coupling Forces
Collet Retention
Physical Shock
High Potential
Aerospace
Vibration
50 G’s, 3 axis, per mil-std-202, method 213, test condition C, wired
Cycled five times from -55°C to 260°C, held for 30 minutes at each
temperature and transferred to the other in 2 minutes or less, with
21°C (70°F), 5000 megohms between adjacent contacts and any
20 hrs. immersion in MIL-H-5606 hydraulic fluid and MIL-L-9236
MIL-DTL-26500, Pyle
Specifications
Connector fully functional for 1000 hours at 200°C (392°F)
.250 ohms backshell of plug to rear of receptacle flange.
Torque required to couple and uncouple mating plugs
(IR 5000 megohms hi-pot 1500 volts-submerged)
and receptacles is not to exceed the values listed:
1000 megohms min. per Mil-std. 202 method 106
Performance requirements of Paragraph 4.5.18
MIL-Std. 202 method 204 condition “D” at R. T.,
ambient internal temperature 238°C (460°F)
8 10 12 14 16 18 20 22
9 10 14 17 23 26 31 38
1500 VRMS mated & unmated at sea level
75 psi. from either direction for 5 seconds.
1000 VRMS mated to 110,000 ft. altitude
to monitor 1 microsecond discontinuity.
Fireproof (Class K of MIL-DTL-5015D)
Sea level 1 inch of mercury, 3 cycles
-55°C (-67°F) and +200°C (+392°F).
1 cu. inch per hr. max. -55°C (-67°F)
lubrication oil. Must meet hi-pot.
0.10 to .015% ozone exposure
MILITARY SPECIFICATIONS
All size contacts 10 lbs. max.
Size 20 contact 20 lbs. min.
Size 16 contact 25 lbs. min.
Size 12 contact 30 lbs. min.
Shell size Torque inch lbs.
no evidence of damage.
contact and shell.
No requirement.
No requirement
2 mu. maximum
-55°C (-67°F)
24
46
®
20 hrs. min., fully functional physically
PYLE CONNECTOR CAPABILITIES
Exceed with ample margin of safety.
and electrically after immersion. No
Comply - monitored for a max. of 1
Without damage to the collet or its
deterioration of resilient material.
Meet MIL-E-5272 condition “B”
microsecond discontinuity.
Exceeds specifications.
Exceeds specifications.
Exceeds specifications
Exceeds specifications
Size 20 –
Size 16 –
Size 12 –
retention means:
Comply
Comply
Comply
Comply
Comply
Comply
Comply
Comply
Comply
Comply
Comply
Comply
160 lbs. min.
140 lbs. min
75 lbs. min.

Related parts for D38999/20WJ19PC