Detailed instructions for terminating single fibre cables with LEMO F2 fibre optic contacts are given in the reference
manual DOC.FO.CF2.0000 supplied with the complete termination workstation (see page 103). After termination
contacts shall be introduced in the main insulator as shown below. For purpose of cleaning they can also be removed.
Insertion and Extraction of the F1 Type Contact
Insertion
The fibre optic contact, male or female, terminated on the
cable, must be inserted into the connector insulator from
the back end until it comes to a stop (step 1 and 2).
Check that the contact is correctly retained by gently pul-
ling on it (step 3).
Insertion and Extraction of the F2 Type Contact
Insertion
The male fibre optic contact terminated on the cable must
be inserted into the connector insulator from the back end
until it comes to a stop. Make sure that the contact is cor-
rectly positioned into the inner antirotation key. Key is in
line with the red dot on the rear of the contact (step 1).
Check that the contact is correctly retained by gently pul-
ling on it (step 2).
For female contacts, the alignment device shall be clipped
onto the fibre optic contacts which is already fitted into
female insulator. This procedure is performed using the ali-
gnment device, reference DCS.F2.035.PN. The alignment
device shall be first installed onto threaded end of the ali-
gnment device (step 3). Then clip the adapter (step 4),
unscrew and remove the alignment device (step 5).
Note: The life time installation of the alignment device is minimum 300 cycles.
82
1)
2)
3)
4)
5)
®
®
1)
2)
3)
Insertion and Extraction of the Fibre Optic Contacts
Extraction
Introduce the extractor, reference DCC.91.312.5LA (see
page 105), in the insulator around the contact and push
until it comes to a stop (step 1 and 2). Gently remove the
fibre optic contact by pulling on the cable (step 3).
Extraction
Reverse the order of the operation previously described.
For female contact remove first the alignment device.
Screw the threaded end of the alignment device reference,
DCS.F2.035.PN (step 1), onto the alignment device and
pull out strongly (step 2).
Then use the extractor reference, DCC.91.312.5LA, intro-
duce it into the insulator and push until it comes to a stop
to compress the contact body (step 3 and 4).
Gently remove the fibre optic contact by pulling on the
cable (step 5).
1)
2)
3)
4)
5)
1)
2)
3)

Related parts for EGG.4K.93L.CLM