Large Wire Contact Terminating Inspection
- - Notes on Customer Manual 409- - 5411 apply
- - Additional allowances are:
1
2
3
D. Wire Exposure
Insulated conductor must extend 0.89 mm [.035 in.] below contact slot.
E. Insulation Range
Insulation range for standard cable connectors should be 1.14 mm [.045 in.] maximum diameter for tools
that mass terminate conductors on one side at a time. For tools that insert one conductor per side at a
time, 1.09 mm [.043 in.] insulation diameter is the maximum. Insulation range for F slot contacts is
1.42 mm [.056 in.] maximum diameter.
F. Workmanship
Minor nicks and scrapes or saddling of the metal bridge are acceptable provided the two slots remain
parallel to each other and perpendicular to the housing. Minor plastic shaving and rolling over of barrier
pads are acceptable provided that contacts are not damaged. Shaving of barrier pads is acceptable up to
0.15 mm [.006 in.] maximum in direction of connector length. Nicks in the insulation above the connector
should not exceed one half of insulation wall thickness.
Terminal perpendicularity of 0.30 mm [.012 in.] to Datum - - Y- - .
Maximum distance after conductor termination is 3.30 mm [.130 in.].
Maximum marking of surface 0.25 mm [.010 in.] from noted edge, typical.
Distance
Section A- - A
2
Wire Must Be Below
Transition Of Lead- - In
To Contact Slot
Barrier Pad
Window Height
Figure 4
Strain- - Relief
Slots
B
3
Section B- - B
Contact Slot
A
A
B
0.30 [.012]
---Y---
114- 6041
Rev B