EP20K600EFC672-2 Altera, EP20K600EFC672-2 Datasheet - Page 113

IC APEX 20KE FPGA 600K 672-FBGA

EP20K600EFC672-2

Manufacturer Part Number
EP20K600EFC672-2
Description
IC APEX 20KE FPGA 600K 672-FBGA
Manufacturer
Altera
Series
APEX-20K®r
Datasheet

Specifications of EP20K600EFC672-2

Number Of Logic Elements/cells
24320
Number Of Labs/clbs
2432
Total Ram Bits
311296
Number Of I /o
508
Number Of Gates
1537000
Voltage - Supply
1.71 V ~ 1.89 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
672-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP20K600EFC672-2
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP20K600EFC672-2
Manufacturer:
XILINX
0
Part Number:
EP20K600EFC672-2
Manufacturer:
ALTERA
0
Part Number:
EP20K600EFC672-2
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP20K600EFC672-2N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP20K600EFC672-2N
Manufacturer:
ALTERA/PBF
Quantity:
4
Part Number:
EP20K600EFC672-2X
Manufacturer:
ATMEL
Quantity:
1
Altera Corporation
Power
Consumption
Configuration &
Operation
LVCMOS
LVTTL
2.5 V
1.8 V
PCI
GTL+
SSTL-3 Class I
SSTL-3 Class II
SSTL-2 Class I
SSTL-2 Class II
LVDS
CTT
AGP
Table 110. Selectable I/O Standard Output Delays
Symbol
Min
-1 Speed Grade
To estimate device power consumption, use the interactive power
calculator on the Altera web site at http://www.altera.com.
The APEX 20K architecture supports several configuration schemes. This
section summarizes the device operating modes and available device
configuration schemes.
Operating Modes
The APEX architecture uses SRAM configuration elements that require
configuration data to be loaded each time the circuit powers up. The
process of physically loading the SRAM data into the device is called
configuration. During initialization, which occurs immediately after
configuration, the device resets registers, enables I/O pins, and begins to
operate as a logic device. The I/O pins are tri-stated during power-up,
and before and during configuration. Together, the configuration and
initialization processes are called command mode; normal device operation
is called user mode.
Before and during device configuration, all I/O pins are pulled to V
by a built-in weak pull-up resistor.
–0.03
–0.48
Max
0.00
0.00
0.00
2.49
0.75
1.39
1.11
1.35
1.00
0.00
0.00
APEX 20K Programmable Logic Device Family Data Sheet
Min
-2 Speed Grade
–0.48
Max
0.00
0.00
0.09
2.98
0.17
0.75
1.51
1.23
1.48
1.12
0.00
0.00
Min
-3 Speed Grade
–0.48
Max
0.00
0.00
0.10
3.03
0.16
0.76
1.50
1.23
1.47
1.12
0.00
0.00
Unit
Min
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
CCIO
113

Related parts for EP20K600EFC672-2