IT1-168S-SV(13) Hirose Electric Co Ltd, IT1-168S-SV(13) Datasheet - Page 14

no-image

IT1-168S-SV(13)

Manufacturer Part Number
IT1-168S-SV(13)
Description
Board to Board / Mezzanine Connectors 168P STR RCP SCK SMT LOC BOS HEAT RES TPE
Manufacturer
Hirose Electric Co Ltd
Datasheet

Specifications of IT1-168S-SV(13)

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
4. Mating Procedure
Step 1
Receptacle Placement on the board –
stationary side
Assure that the orientation posts are aligned
with the holes on the board.
When specifying receptacle assemblies without
the orientation posts exercise extra caution to
assure correct orientation and connection with
the solder pads.
Step 2
Insertion of the Transmission Module
Fully insert the Transmission Module in the
board-installed receptacle assembly.
It is critical that the insertion is done straight
and uniformly.
Step 3
Mating/un-mating
Assure that the receptacle assembly is correctly
aligned with the Transmission Module.
Fully insert the receptacle assembly on the
Transmission Module.
It is critical that the insertion is done straight
and uniformly.
Step 4
Follow the procedure described below.
Note:¡The transmission module must be fully inserted into receptacle assembly already placed and soldered to a board.
¡The Transmission Module cannot be exposed to heat temperatures of the soldering process.
IT1 Series High Speed, Matched-Impedance, Parallel Board-to-board Connector System
Connection completed
A307

Related parts for IT1-168S-SV(13)