10-036982-003 Amphenol, 10-036982-003 Datasheet

no-image

10-036982-003

Manufacturer Part Number
10-036982-003
Description
Terminals PIN 16L NON-FILLED
Manufacturer
Amphenol
Series
QWLDr
Datasheet

Specifications of 10-036982-003

Gender
Female
Contact Plating
Nickel
Mounting Angle
Straight
Termination Style
Solder
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
MIL-C-22992, Class L Accessories
contacts
All dimensions for reference only.
*Order by MS part number listed for either socket or pin.
M39029/49-335 M39029/48-327
M39029/49-333 M39029/48-323
M39029/49-331 M39029/48-320
M39029/49-329 M39029/48-317
M39029/49-332 M39029/48-322
M39029/49-330 M39029/48-319
M39029/48
pin contact
M39029/49
socket contact
Number*
MS Part
Socket
---
---
---
---
H
M39029/48-328
M39029/48-324
M39029/48-321
M39029/48-318
MS Part
Number
Pin
C
H
Contact
4/0N
1/0N
Size
1/0
4/0
4N
6N
4G
6G
4
6
+.031
–.000
.750
C
Wire
Well
Size
4/0
4/0
1
1
4
4
6
6
4
6
3.325
3.207
3.325
2.786
2.904
2.786
2.904
2.856
2.856
3.207
Ref.
.750
+.031
–.000
A
REF
2.097
2.215
2.097
2.215
1.738
1.856
1.738
1.856
1.746
1.746
±.005
A
B
12
.641
.641
.406
.406
.281 ±.002
.281 ±.002
.234 ±.002
.234 ±.002
.281 ±.002
.234 ±.002
REF
K
B
Dia
C
+.004
–.003
+.004
–.003
+.004
–.003
+.004
–.003
±.001
.500
.500
.357
.357
.225
.225
.178
.178
.225
.178
Dia
J
D
.781 ± .003
.781 ± .003
.609 ± .003
.609 ± .003
.417 ± .002
.417 ± .002
.342 ± .002
.342 ± .002
.417 ± .002
.342 ± .002
Dia
G
.750
.750
.506
.506
.374 ± .002
.374 ± .002
.312 ± .002
.312 ± .002
.374 ± .002
.312 ± .002
Dia
H
+.004
–.003
+.004
–.003
+.004
–.003
+.004
–.003
G
D
G
1.283
1.283
1.158
1/158
1.752
1.752
±.005
---
---
---
---
J
2.393
2.393
2.206
2.206
2.862
2.862
Ref
---
---
---
---
K

Related parts for 10-036982-003

10-036982-003 Summary of contents

Page 1

MIL-C-22992, Class L Accessories contacts M39029/48 pin contact H C M39029/49 socket contact H All dimensions for reference only. Socket Pin MS Part MS Part Contact Number* Number Size M39029/49-335 M39029/48-327 --- M39029/48-328 4/0N M39029/49-333 M39029/48-323 1/0 --- M39029/48-324 1/0N ...

Page 2

... MS3348 MS3348 MS3348 MS3348 MS3348 MS3348 MS3348 MS3348-6 -10L 6 10 MS3348-4/0-2/0L 4/0 2/0 * Order by MS part number listed. MS90562 contact removal tool All dimensions for reference only. A Dia MS Part Contact +.000 Number* Size –.002 MS90562-1 4/0 .790 MS90562-2 2/0 ...

Page 3

... This gland must be used with MS90561 strain relief. B Min Dia Cable +.020 C Dia –.000 ±.010 Ref. 1.130 1.034 1.005 1.047 1.034 .922 1.342 1.034 1.217 1.438 1.160 1.313 1.516 1.160 1.391 1 ...

Page 4

MIL-C-22992, Class L Accessories protective covers MS90563 protective covers used with: MS90555 wall mount receptacle MS90557 cable connecting receptacle All dimensions for reference only. Use A Thread MS with Class 2B Part Shell .1428P-.2857L Number* Size Double Stub MS90563-1( ) ...

Page 5

... MIL-C-22992, QWLD Accessories M85049 or 10-522958 cable sealing adapters (plug 1.500 MAX 1.500 MAX B L 1.500 MAX LEFT HAND C G SECTION A-A Type LEFT HAND G Q Type II D LEFT HAND G C SECTION R-R Type III ...

Page 6

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 7

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 8

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 9

... MIL-C-22992, QWLD Accessories M85049 or 10-524959 cable sealing adapters (receptacle LEFT HAND C G SECTION A-A Type LEFT HAND G Q Type II D LEFT HAND G C SECTION R-R Type III ...

Page 10

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 11

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 12

... Ordering procedure: Locate shell size needed (Column 4); select cable diameter range to be accommodated within the shell size (column 5); order by either MS part number (column 1) or Proprietary part number (column 3). MS numbers shown are non-conductive finish. To order conductive finish, substitute “W” for “A” in the part number listed. 10- numbers shown are non-conductive finish. To order conductive finish, substitute prefix 88-. Cable Used ...

Page 13

... MIL-C-22992, QWLD Accessories 10-350695 adapter, 10-350349 cable clamp 10-350695-XX( ) adapter C 10-350349-( )3 cable clamp MS3420-( )A sleeve LEFT HAND E A ...

Page 14

... MS3057-28C 2.250-16UN * To attach the cable clamp to the left hand accessory threads of QWLD connectors, adapter 10-350695-XX is needed. Order this proprietary adapter from column 2 and suffix the part number with the finish desired, listed in the finish chart below. ** Order MS clamp (column 3) to accommodate the cable type being used. Standard finish on the clamp is olive drab, cadmium plate. ...

Page 15

... MIL-C-22992, QWLD Accessories protective covers MS17350 10-524915-( ) plug protective cover C MS17349-XXB 10-524916-( ) receptacle protective cover C MS17349-XXA 10-524917-( ) receptacle protective cover ...

Page 16

... Proprietary covers as per coded part number example: PART NUMBER 10-524915 Base Number - Max 10-524915 designates plug cover with chain 10-524916 designates receptacle cover with chain 10-524917 designates receptacle cover with chain and attaching ring 2. Cover Size - Shell size of connector with which cover is used. 3. Finish - ...

Page 17

... Order by part number listed to accommodate shell size being used. R (TP) R (TP Dia Part ±.010 ±.010 Number** .906 .172 10-40450-14 ...

Page 18

... Number* Size 10-242067-13 10-242067-15 10-242067-17 10-242067-18 10-242067-20 10-242067-22 10-242067-24 10-242067-28 10-242067-32 10-242067-36 10-242067-40 10-242067-44 10-242067-48( ) *Order by part number listed to accommodate shell size being used. To complete part number add suffix for finish desired from table below LEFT HAND +.010 .125 –.000 ...

Page 19

... D D Dia L ±.010 ±.010 .484 1.273 .609 1.273 .734 1.273 .859 1.242 .984 1.242 1.109 1.242 1.234 1.179 1.427 1 ...

Page 20

... Pressure Altitude† Level Conditions 50,000 Feet Minimum Minimum Flashover Test Flashover Test Voltage Voltage Voltage Voltage AC(RMS) AC(RMS) AC(RMS) AC(RMS) 1400 1000 550 400 2800 2000 800 600 3600 2800 900 675 4500 3500 1000 750 5700 4500 1100 825 ...

Page 21

... Amphenol proprietary number. Gold plated contacts are also available (See how to order, page 22). Part Pin/ Number Socket 10-40557 Pin 10-40556 or Socket 10-597109-171 10-40561 Pin 10-40560 or Socket 10-597109-131 10-40792 Pin 10-40793 Socket 10-40564 Pin 10-40565 Socket 10-40562 Pin 10-40563 Socket * When using wire adapter sleeve shown. ...

Page 22

... QWLD application tools Complete installation instructions (L-615) for Amphenol QWLD Series Connectors are available on request. The following data includes information pertaining to the application tools which have been established for crimp- ing, inserting and removing crimp contacts used in QWLD Series Connectors. Crimping ...