MNG18-10R/LK (BULK) 3M, MNG18-10R/LK (BULK) Datasheet - Page 2

no-image

MNG18-10R/LK (BULK)

Manufacturer Part Number
MNG18-10R/LK (BULK)
Description
Terminals RNG TERM 22-18 #10
Manufacturer
3M
Type
Ring Tongue Terminalr
Datasheet

Specifications of MNG18-10R/LK (BULK)

Product
Rings
Wire Size (awg)
22-18
Stud / Tab Size
# 10
Insulation
Insulated
Contact Plating
Tin
Contact Material
Copper
Termination Style
Ring Tongue
Insulation Material
Nylon
Size
0.92 in x 0.31 in
Wire Gauge Range
22-18
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
05400701071 80610035380 MNG18-10R/LK
Electrical Products Division
6801 River Place Blvd.
Austin, TX 78726-9000
http://www.3M.com/elpd
Specifications
Wire Size:
Barrel Seam:
Max. Voltage Rating:
Max. Temperature Rating:
Max. Current:
Insulator Material:
Terminal Material:
Terminal Plating:
Installation Information
UL Listed and CSA Certified for use on stranded copper
(AWG) wire only.
Strip away the end 3/8 inch of wire insulation.
Make the crimp in the proper station of a recommended
3M crimp tool: TH-440, TH-450 (scissor style), or
TR-482, TR-490 (ratchet style) hand tools.
IMPORTANT NOTICE
Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability
associated with such use.
Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of purchase.
3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be,
at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will
not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential
regardless of the legal theory asserted.
UNDERWRITERS
LABORATORIES
STANDARD NO. UL 486A
3M FILE NO. E23438
3M and Scotchlok are trademarks of 3M.
WARNING
Turn power off before installing or removing terminal. All electrical
work should be done according to appropriate electrical codes.
is a trademark of Underwriters Laboratories.
is a trademark of Canadian Standards Association.
Insulation Support Crimp
(Mechanical)
Barrel Crimp (Electrical)
See Table Above
Butted with Insulation Grip
600 V Building Wire
1000 V Signs, Fixtures
and Luminaires
221˚F (105˚C)
Same as Wire
Nylon
ETP Copper
Tin
CANADIAN STANDARDS
ASSOCIATION
STANDARD NO. C22.2
NO. 0. 65
3M FILE NO. LR22190
Engineering Specification
Crimp-type terminals shall, electrically and
mechanically, connect to a pre-stripped end of a
stranded copper wire: and have a flat tongue portion
with a central opening for mounting around a screw or
stud.
The terminal line shall offer tongue variations in hole
(stud) size (6, 8 10, etc.) and configuration (ring, fork,
block fork, flanged block fork, locking fork, etc.): and
barrel variations in wire (AWG) size (22-18, 16-14,
12-10, etc.) and construction (non-insulated brazed
seam, vinyl insulated butted seam, nylon insulated
with insulation grip, etc.). The terminal line shall have
regulatory agency coverage (UL Listing, CSA
Certification). The terminal tongue shall be marked
with the wire range and manufacturer’s symbol ( ).
The nylon-insulated, ring tongue terminal with
insulation grip shall be tin-plated, annealed copper,
with the tongue having a specified stud hole (size 4
thru 3/8 in.) and a butted seam barrel with a tin plated
brass, funnel entry insulation grip, covered by a
molded nylon sleeve, color coded and sized for a
specified (AWG) wire range (22-18, 16-14, 12-10).
Insulated terminals shall be UL Listed and CSA
Certified for 600 Volts maximum building wire: 1000
Volts maximum in signs, fixtures and luminaries and
have a maximum operating temperature of 221°F
(105°C).
© 3M 2002 78-8126-0520-8-A