E39-L148 Omron, E39-L148 Datasheet

Sensor Hardware & Accessories E3X-NAV MOUNTING BRACKET

E39-L148

Manufacturer Part Number
E39-L148
Description
Sensor Hardware & Accessories E3X-NAV MOUNTING BRACKET
Manufacturer
Omron
Datasheets

Specifications of E39-L148

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
The Ultimate Fiber Amplifier for
Maximum Ease of Use and High
Performance
Features
Models with New Connector System
Reduces Wiring, Saves Space, and Makes
Maintenance Easier
In Amplifiers with wire-saving connectors, the power supply is
distributed to 1-conductor slave connectors through a 3-
conductor master connector. This design has three major
advantages.
1. Wiring time is significantly reduced.
2. Relay connectors are unnecessary, so wiring takes up less
3. Storage and maintenance are simpler because it isn't
Simplified Connector Design
Up to 16 Amplifiers can
be connected.
Digital Fiber Amplifier
E3X-DA-N
space and costs are reduced.
necessary to distinguish between master connector and
slave connectors on the Amplifier.
Be sure to read Safety Precautions
on page 23.
Master connector
http://www.ia.omron.com/
First in the Industry Patent Pending
Optical
communi-
cations
Power
supply pin
Slave connector
* UL certification including UL 991 testing and evaluation • Applicable standards: UL 3121-1
• Additional application testing and evaluations standards: UL 991 and SEMI S2-0200S
Super Digital Display with Auto Power
Control (APC) Circuit
The passage of time causes the intensity of the Sensor's light-
emitting LED elements to deteriorate, which may make stable
detection impossible.
The E3X-DA-N is the first series of Fiber Sensors to use an
Auto Power Control (APC) circuit. This achieves strict
detection by eliminating fluctuation in the digital value and is
ideal for subtle detection such as stable detection of liquid-
crystal glass.
E3X-DA-N Series
Previous Digital
Fiber Amplifiers
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Threshold
Threshold
Incident level
Incident level
3000
3000
Unstable detection
Time
Time
Stable detection
First in the Industry
UL991*
1

Related parts for E39-L148

E39-L148 Summary of contents

Page 1

... Incident level 3000 Previous Digital Threshold Fiber Amplifiers Incident level 3000 E3X-DA-N Series Threshold (c)Copyright OMRON Corporation 2007 All Rights Reserved. UL991* First in the Industry Unstable detection Time Stable detection Time 1 ...

Page 2

... Channel setting flash the Sensor head and section display the amplifier channels. Light intensity monitor Channel 5 Threshold Channel 4 Channel 3 Channel 2 Channel 1 Operation keys Battery monitor Head (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Eco-mode Group teaching Optical communications 2 ...

Page 3

... E3X-CN12 Master E3X-CN11 Slave E3X-CN12 Master E3X-CN11 Slave E3X-CN12 ON/OFF output XS3F-M421-40@-A XS3F-M422-40@-A Master E3X-CN21 Slave E3X-CN22 (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Model NPN output PNP output E3X-DA11-N E3X-DA41-N E3X-DA21-N E3X-DA51-N E3X-DAB11-N E3X-DAB41-N E3X-DAG11-N E3X-DAG41-N E3X-DAH11-N E3X-DAH41-N E3X-DA11D ...

Page 4

... Applicable Connectors (Order Separately) Master Connector PNP E3X-DA8 E3X-DAB8 + E3X-DAG8 E3X-CN11 E3X-DAH8 --- E3X-DA9 E3X-CN21 E3X-DA8TW + 1 Master Connector Appearance Cable type 4-wire connection (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Slave Connector E3X-CN12 E3X-CN22 4 Slave Connectors Model XS3F-M421-402-A XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A 4 ...

Page 5

... Power supply method: chargeable battery Mobile Console Head Cable (1.5 m) Model Quantity Remarks E39-L143 --- 1 E39-L148 (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Operating Instructions Sticker Model Remarks Attach near the Sensor. E39-Y1 ➜Refer to page 25. End Plate Appearance ...

Page 6

... E3X -DA21-N -DAB11-N -DAG11-N E3X E3X E3X -DA51-N -DAB41-N -DAG41-N Blue LED Green LED (470 nm) (525 nm) --- (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N For dimensions, refer to page 26 to 29. Water- Infrared Twin-output resistant models models models E3X E3X E3X -DAH11-N -DA11V ...

Page 7

... E3X E3X -DA51-N -DAB41-N -DAG41-N Monitor-out- Mark-detecting models put models E3X-DA7 E3X-DAB6 E3X-DAG6 E3X-DA9 E3X-DAB8 E3X-DAG8 E3X-CN12 Approx (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Water- Infrared Twin-output resistant models models models E3X E3X E3X -DAH11-N -DA11V -DA11TW E3X E3X ...

Page 8

... HIGH 2 3- 200 ms 270 or 0 570 μ 400 ms 90 120 Differential-output Models (Edge-detection Models) Pre-wired E3X-DA11D (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Standard object LOW (mm (min. sensing 1 to 200 ms object *2: opaque) 0 400 ms 180 (1260) 240 (1680) 1 dia. (0.01 dia ...

Page 9

... Long-distance Lens Unit) 800 X 600 Y 400 Standard 200 Distance X (m) −200 Super-high speed −400 Super-long distance −600 −800 Through-beam E32-TC200 + E39-F1 (separately sold Long-distance Lens Unit) 600 X Y 400 200 Standard Distance X (m) −200 −400 High speed Super-long distance −600 Through-beam E32-T21R ...

Page 10

... Distance High speed −100 X (mm) Standard −200 Super-long distance −300 Through-beam E32-T61 + E39-F1 (separately sold Long-distance Lens Unit) 600 X Y 400 200 Standard Distance X (m) −200 High speed −400 Super-long distance − ...

Page 11

... Standard Super-long distance −0.6 Reflective E32-C31 Standard 100 Distance −10 High speed X (mm) −20 Super-long distance −30 (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Reflective E32-D11R 50 X Standard 100 200 300 400 500 −10 Distance X (mm) −20 −30 −40 Super-long distance High speed − ...

Page 12

... Reflective E32-D36P1 120 X Standard 200 300 500 600 100 400 Distance −40 X (mm) −80 High speed Super-long distance −120 (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Reflective E32-D14LR Super-high 0 speed 40 80 120 160 200 −5 Distance X (mm) −10 Standard − ...

Page 13

... Distance (mm) Reflective E32-DC200 100 Distance (mm) (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Reflective E32-D21L 1,000 500 300 100 50 30 Super-long distance Oper- 1 ating 0.5 level 0.3 Standard Super-high speed 0 100 150 200 250 300 ...

Page 14

... Distance −10 X (mm) −20 −30 Super-long distance −40 For other information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353). http://www.ia.omron.com/ Through-beam E32-TC200 + E39-F1(separately sold Long-distance Lens Unit) 200 X 150 Y 100 50 0 0.5 1 1.5 2 2.5 Distance − ...

Page 15

... Time ON Output 1 OFF ON Output 2 OFF (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N (In the following examples, threshold 1 is set to 3,000, and threshold 2 is set to 1,000.) Output Patterns for Area Sensing This series includes models equipped with area sensing functionality, a first for Digital Fiber Amplifiers ...

Page 16

... Classifi- Wire colors cation Wire colors Brown Brown White Blue White Black DC Blue Black Note: Pin 2 is not used. (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Output circuit Operation indicator (orange) Brown 1 Load Black 4 Photo- Control output electric 12 to Sensor ...

Page 17

... Classi- Wire colors fication Wire colors Brown Brown White Blue White Black DC Blue Black Note: Pin 2 is not used. (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Output circuit Operation indicator (orange) Brown 1 Photo- Control output electric 12 to Black 4 Sensor 24 VDC ...

Page 18

... Setting Buttons TEACH MODE Channel-selection Switch Use to switch between channels 1 and 2. (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N appropriate output type depending on the application. 2. This wiring is for the K3NX with DC power supply specifications and the Monitor (Analog) Sensor with DC power supply specifications. Check respective power supply specifications before wiring ...

Page 19

... Initial Reset (SET Mode) Set the mode selector to SET. SET MODE MODE Sensitivity decrement with threshold increment ADJ mode (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Digital incident level (4000 max.) TEACH reset to zero again: TEACH 1 s TEACH MODE Hold down both for 3 s ...

Page 20

... Displayed as "t." Adjustable in 1-ms units for and in 5-ms units for higher. Displayed as "L." MODE Displayed as "H." (Factory setting) (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Available with: E3X-DA21-N E3X-DA51-N E3X-DA7 E3X-DA9 Setting upper limit Alternates between for monitoring " ...

Page 21

... MODE 2 s Displayed as “F.” MODE TEACH 2 s TEACH TEACH TEACH MODE 2 s (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Timer function Displayed as “t.” (Factory setting) TEACH Adjustable in 1-ms units for and in 5-ms units for higher. 200 TEACH Flashing setting Displayed as “ ...

Page 22

... Teaching is complete when the green level display is lit. The level display will display the digital 5 incident level later. (The red level display will flash if a teaching error occurs.) Set to RUN mode. 6 (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N CH1 CH2 Operation SET Object TEACH 1 s ...

Page 23

... EEPROM Writing Error If the data is not written to the EEPROM correctly due to a power failure during teaching or static-electric noise, repeat the whole teaching procedure. (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Protective cover ...

Page 24

... Remove the clip by rotating the Amplifier. When using the E3X-DA-N with the Mobile Console, mount the End Plate in the way shown below. Pull Strengths for Connectors (Including Cables) E3X-CN11, E3X-CN21, E3X-CN22 max. E3X-CN12 max. Lever (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Rotate End Plate 24 ...

Page 25

... Accessories Operating Instructions Sticker E39-Y1 • Attach near the Sensor. • 1 English and 1 Japanese sticker per set • Material: Front side: Paper, Reverse side: Adhesive tape Japanese Sticker 100 English Sticker 100 http://www.ia.omron.com (c)Copyright OMRON Corporation 2007 All Rights Reserved. ...

Page 26

... Threshold level indicator * 2.8 11.2 Hole for optical communi- cations 6.6 Mounting Bracket (E39-L148) (order separately) SUS304 stainless steel 5.4 *1. The Mounting Bracket can also be used on side A. *2. 4-dia. vinyl-insulated round cable with 3 conductors 2 (Conductor cross section: 0 Insulation diameter: 1.1 mm). ...

Page 27

... Hole for optical commu- 22.4 16 nications 13 34.8 Two, 3.2-dia. holes E39-L143 Mounting Bracket (order separately) SUS304 stainless steel 3.4 4.4 22.4 16 Incident level indicator Threshold level indicator Operation indicator 13.05 17.15 4.9 × 14.7 3 64.3 Two, 2 ...

Page 28

... OMRON Corporation 2007 All Rights Reserved. E3X-DA-N Incident level indicator Threshold level indicator a *1 81.5 2.8 M8 11.2 Hole for optical 16 communi- 37 cations 67.2 11 E39-L148 Mounting Bracket (order separately) 16 SUS304 stainless steel 3.4 5.4 3.4 64.3 31.5 14 5.5 36.7 Hole for optical communications 71 67.5 64.3 E3X-CN22: 4 ...

Page 29

... AC adapter jack Communications jack Menu indicators Connection indicator 52.8 Channel indicator Mode display 136 Escape button Power supply button 50 (c)Copyright OMRON Corporation 2007 All Rights Reserved. E3X-DA-N 4 dia ±2 ±2 + Insulation diameter: 1.1 mm Insulation diameter: 1.1 mm). E3X-CN12: 2.6 dia. ...

Page 30

... Example: Incorrect Polarity Wiring Load - Brown Black Sensor + Blue • AC 2-wire Sensors Example: E3E2 etc. Brown 12 to 24VDC Sensor Black Sensor 0V Blue (c)Copyright OMRON Corporation 2007 All Rights Reserved. --- Load (Load short circuit) Brown Blue Load Load Brown Sensor Black Blue - Black + Brown Blue + ...

Page 31

... E3Z-TA to allow close-proximity 2 prevention mounting Sensors. filter. Mutual Interference Prevention Polarizing Filter: E39-E11 Separate Check the parallel movement distance range in the Sensors to catalog, verify the set distance between adjacent distance where Sensors, and install the Sensors accordingly at a interference distance at least 1 ...

Page 32

... N max. Work Required for Unconnected Leads Unused leads for self-diagnosis outputs or other special functions should be cut and wrapped with insulating tape to prevent contact with other terminals. on (c)Copyright OMRON Corporation 2007 All Rights Reserved. After countermeasure Insert an insulator. +V Inverter motor Sensor ...

Page 33

... Result The testing conditions of the standard cable and robot cable are different. Refer to the values in the above table to check bend-resistant performance under actual working conditions. (c)Copyright OMRON Corporation 2007 All Rights Reserved. (2) (1) (3) θ θ R Weight Robot cable: Strong, ...

Page 34

... Lock released position Emitter Protective cover Optical axis: Mechanical axis: The axis perpendicular to the center of the lens. Emitter Emission beam (c)Copyright OMRON Corporation 2007 All Rights Reserved. Receiver Incident indicator or Operation indicator ON OFF Optimum value ...

Page 35

... When using adhesive tape on the rear face, apply it after washing away oil and dust with detergent. The Reflector cannot be mounted if there is any oil or dirt remaining. (2) Do not press on the E39-RS1/RS2/RS3 with metal or a fingernail.This may weaken performance. (3) This Sensor cannot be used in locations where oil or chemicals may splash on the Sensor ...

Page 36

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords