LKF1aM-12V-1-8 Panasonic, LKF1aM-12V-1-8 Datasheet

no-image

LKF1aM-12V-1-8

Manufacturer Part Number
LKF1aM-12V-1-8
Description
Low Signal Relays - PCB LK-F Relay
Manufacturer
Panasonic
Datasheet

Specifications of LKF1aM-12V-1-8

Contact Form
1 Form A
Coil Voltage
12 VDC
Coil Type
Single Side Stable
Power Consumption
250 mW
Maximum Switching Current
8 A
LK-F
FEATURES
• Low profile (10 mm height)
Height reduced 60% compared with
previous product*.
• Nominal switching capacity: 5A,
8A 277V AC
ORDERING INFORMATION
Contact arrangement
1a: 1 Form A
Nominal operating power
M: 250mW
Operation noise
Nil:
Q:
Nominal coil voltage (DC)
5, 9, 12, 24V
TV standard
5: TV-5
8: TV-8
Note: Certified by UL/C-UL, TÜV and SEMKO
.984 inch
*Previous product: LK-S relay
Compliance with RoHS Directive
25 mm
Standard type
Silent type
Previous product*
(LK-S)
LKF 1a
10 mm
(including stand off)
Low profile LK-F
.394 inch
M
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
• TV standards compatible: TV-5 and
TV-8
• TV-5 type: 78 A inrush current and
switching possible at 5 A rated current.
• TV-8 type: 118 A inrush current and
switching possible at 8 A rated current.
• Line up includes silent type
Approx. 10 dB less sound pressure than
LK-S relay.
1
10mm flat power relays
Silent type is available
30
20
10
30
20
10
0
0
30 35 40 45 50 55 60 65 70 75 80 85
25
2
TV-5, TV-8 rated
30
35 40 45 50 55 60 65 70 75 80
V
When operate
When release
Sound pressure, dB
Sound pressure, dB
1
LK-F relay (silent)
LK-S relay
LK-F relay (silent)
LK-S relay
5
• High sensitivity: 250mW
Ideal for device power reduction
• 0.7 mm
• Conforms to various safety
standards
UL/C-UL, TÜV and SEMKO
TYPICAL APPLICATIONS
• Flat-panel TVs
• Audio visual equipment
• Other slim profile devices
LK-F RELAYS
.028 inch
stand off height
.028
0.7
mm
inch

Related parts for LKF1aM-12V-1-8

LKF1aM-12V-1-8 Summary of contents

Page 1

... LK-S relay Sound pressure All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. LK-F RELAYS • High sensitivity: 250mW Ideal for device power reduction • 0.7 mm .028 inch stand off height 0.7 .028 mm inch • Conforms to various safety standards UL/C-UL, TÜV and SEMKO TYPICAL APPLICATIONS • ...

Page 2

... Hz at double amplitude of 1.5 mm (Detection time: 10 s.) Min. 10 (at 20 times/min.) 5 Ambient temperature: – + Humidity 85% R.H. (Not freezing and condensing at low temperature); Part No. TV-8 type Standard type LKF1aM-5V-1-8 LKF1aMQ-5V-1-8 LKF1aM-9V-1-8 LKF1aMQ-9V-1-8 LKF1aM-12V-1-8 LKF1aMQ-12V-1-8 LKF1aM-24V-1-8 LKF1aMQ-24V-1-8 Coil resistance Nominal operating [ 10%] ( power 100 324 250mW 576 2,304 Specifi ...

Page 3

... Pick-up voltage 6 Drop-out voltage 2.5 No. of operations, 10 All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. 2-(2). Coil temperature rise (TV-8 type) Sample: LKF1aMQ-12V-1-8, 6 pcs. Point measured: coil inside Contact current: 0A 140 60 80 100 Coil applied voltage, %V 120 Change of contact resistance ...

Page 4

... With diode Microphone 50mm 1.969inch Mat Relay 5-(2). Operation noise distribution LK-F (Height: 10 mm, Standard) Measuring conditions Sample: LKF1aM-12V-1-5, 50pcs Background noise: approx. 20dB Coil voltage: 12V DC Equipment setting: “A” weighted Single part (refer to figure below) With diode Microphone 50mm 1.969inch ...

Page 5

... Certification 1) This relay is UL/C-UL certified. UL/C-UL standards: TV 277 277 V AC All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. mark can be downloaded from: http://panasonic-electric-works.net/ac PC board pattern (Bottom view) 2-0.9 dia. 2-.035 dia. 18.25 .719 19 ...

Related keywords