G6H-2-100 DC5 Omron, G6H-2-100 DC5 Datasheet - Page 3

Low Signal Relays - PCB 1A Relay PC MNT DPDT 5VDC

G6H-2-100 DC5

Manufacturer Part Number
G6H-2-100 DC5
Description
Low Signal Relays - PCB 1A Relay PC MNT DPDT 5VDC
Manufacturer
Omron
Series
G6Hr
Datasheet

Specifications of G6H-2-100 DC5

Contact Form
2 Form C
Coil Voltage
5 VDC
Coil Type
Non-Latching
Power Consumption
140 mW
Termination Style
Solder Pin
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
5DC 5DC, G6H-2-100 G6H21005DC,
■ Characteristics
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
■ Approvals
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C
Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, TUV) may be different from the performance characteristics
Contact resistance (See note 1)
Operate (set) time (See note 2)
Release (reset) time (See note 2)
Min. set/reset signal width
Operating frequency
(max.)
Insulation resistance (See note 3)
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
G6H-2(F)
G6HU-2
G6HK-2
2. Values in parentheses are typical values unless otherwise stated.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength.
4. The above values are initial values.
2. In the interest of product improvement, specifications are subject to change.
(The insulation resistance between the set and reset coil (G6HK-2), however, is 100MΩ min. when measured with a 125-VDC megohmmeter).
individually defined in this catalog.
Type
Mechanical
Electrical
Mechanical durability 10 to 55 Hz; 5 mm double amplitude
Malfunction durability 10 to 55 Hz; 3 mm double amplitude
Mechanical durability 1,000 m/s
Malfunction durability 500 m/s
Mechanical
Electrical
DPDT
50 mΩ max. (through-hole); 60 mΩ max. (surface mount)
Non-latching: 3 ms max. (approx. 2.0 ms)
Latching: 3ms max. (approx. 1.5 ms)
Non-latching: 2 ms max. (approx. 1.0 ms)
Latching: 3ms max. (approx. 1.5 ms)
5ms min. (at 23°C)
36,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ max. (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same pole
125 VAC, 50/60 Hz for 1 minute between set and reset coils (G6HK-2)
1,500 V (10 x 160 μs) between contacts of same polarity (conforms to FCC Part 68)
-40° to 70°C with no icing
5% to 85% RH
100 million operations min. (at 36,000 operations/hr)
200,000 operations min. (at 1,800 operations/hr) See “Characteristic Data”
Approx. 1.5 g
Contact form
DISCONTINUED
2
(approx. 50 G)
2
(approx. 100 G)
1.50 to 48 VDC
Coil rating
Low Signal Relay
2 A, 30 VDC
0.30 A, 110 VDC
0.50 A, 125 VAC
Contact ratings
G6H
51