HP-HOLDDOWN-CLIP Panasonic, HP-HOLDDOWN-CLIP Datasheet
HP-HOLDDOWN-CLIP
Specifications of HP-HOLDDOWN-CLIP
Related parts for HP-HOLDDOWN-CLIP
HP-HOLDDOWN-CLIP Summary of contents
Page 1
... To enable use with DIN rails, DIN terminal sockets are also available. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 10 AMP POWER RELAY TYPICAL APPLICATIONS HP relays enjoy wide use in various applications, particularly in automation controls and remote controls. Applications include: 1. Industrial machinery ...
Page 2
... All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 3 Form C 4 Form C Part No. Part No. HP3-AC6V HP4-AC6V-F HP3-AC12V HP4-AC12V-F HP3-AC24V HP4-AC24V-F HP3-AC48V HP4-AC48V-F HP3-AC100V HP4-AC100V-F HP3-AC115V HP4-AC115V-F HP3-AC200V HP4-AC200V-F HP3-AC220V HP4-AC220V-F HP3-AC240V HP4-AC240V-F HP3-DC6V HP4-DC6V-F HP3-DC12V HP4-DC12V-F HP3-DC24V HP4-DC24V-F HP3-DC48V HP4-DC48V-F HP3-DC100V HP4-DC100V-F HP3-DC110V HP4-DC110V-F ...
Page 3
... HP2-TM-DC24V HP2-TM-DC48V HP2-TM-DC100V HP2-TM-DC110V 3 Form C Part No. HP3-ML-AC100V HP3-ML-AC115V HP3-ML-AC200V HP3-ML-AC220V HP3-ML-AC240V HP3-ML-DC100V HP3-ML-DC110V HP 4 Form C Part No. HP4-L-AC6V-F HP4-L-AC12V-F HP4-L-AC24V-F HP4-L-AC100V-F HP4-L-AC115V-F HP4-L-AC200V-F HP4-L-AC220V-F HP4-L-AC240V-F HP4-L-DC6V-F HP4-L-DC12V-F HP4-L-DC24V-F HP4-L-DC48V-F HP4-L-DC100V-F HP4-L-DC110V-F 3 Form C (direct mount type) Part No. HP3-M-AC6V HP3-M-AC12V HP3-M-AC24V HP3-M-AC48V HP3-M-AC100V HP3-M-AC115V ...
Page 4
... HP RATING 1. Coil data 1) AC coils Nominal coil current Contact Nominal coil (mA) arrangement voltage 50Hz 6V AC 349mA 12V AC 181.2mA 24V AC 94mA 48V AC 46.5mA 2 Form C 100V AC 25.3mA 115V AC 23.1mA 200V AC 12.4mA 220V AC 10.6mA 240V AC 10.0mA 6V AC 594mA 12V AC 297mA 24V AC 148.7mA 48V AC 74.2mA ...
Page 5
... DC Inductive (A) Resistive (A) 7 — 5 0.5 3 0.3 0.6 0.1 Specifications – +104 F 250V AC Expected life Inductive (A) (cos =0.4) 7.5 Min Min Min. 10 0.4 Min 125V DC Expected life Inductive (A) — Min 0.4 Min 0.2 Min. 10 0.06 Min 4.41oz ...
Page 6
... Coil terminal No. and polarity (DC type) Polarity HP2 (+) 7 Terminal No. (–) 2 Schematic (Bottom view Compatible with tab terminal #205 series receptacle. Tolerance .079 inch: 0.2 .008 .079 to .354 inch: 0.5 .020 .354 to .787 inch: 1 .039 .787 inch: 1.5 .059 HP3 HP4 ...
Page 7
... Schematic (Bottom view Compatible with tab terminal #205 series receptacle. Tolerance .079 inch: 0.2 .008 .079 to .354 inch: 0.5 .020 .354 to .787 inch: 1 .039 .787 inch: 1.5 .059 ...
Page 8
... HP TM type (2 Form C) Dimension: Tolerance Max. 2mm .079 inch: 0.2 .008 2 to 9mm .079 to .354 inch: 0.5 .020 9 to 20mm .354 to .787 inch: 1 .039 Min. 20mm .787 inch: 1.5 .059 Direct mounting type (3 Form C) .197 Dimension: Tolerance Max. 2mm .079 inch: ...