D2RV Omron, D2RV Datasheet - Page 2

no-image

D2RV

Manufacturer Part Number
D2RV
Description
Basic / Snap Action / Limit Switches Reed Pin plunger 50g 0.1 A SPST-NO
Manufacturer
Omron
Series
D2RVr
Type
Reed Miniature Basicr
Datasheets

Specifications of D2RV

Contact Form
SPST - NO
Contact Rating
0.25 Amp at 100 VoltsDC
Actuator
Plunger, Pin
Operating Force
0.49 N (50 g)
Termination Style
Solder
Ingress Protection
IP40
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
D2RV
Specifications
Note:
2
Switching voltage
Switching current
Contact capacity
SPST-NO
Operating speed
Operating frequency
Insulation resistance (see note 2)
Contact resistance (initial value)
Dielectric strength
Vibration resistance (see note 3)
Shock resistance (see note 3)
Durability (see note 4)
Degree of protection
Degree of protection against elec-
tric shock
Proof tracking index (PTI)
Ambient operating temperature
Ambient operating humidity
Weight
Ratings
Characteristics
Contact Form
1. The data given above are initial values.
2. Insulation resistance between terminals of the same polarity is measured at 100 VDC.
3. For the pin plunger models, the above values apply for use at both the free position and total travel position. For the lever models,
4. For testing conditions, contact your OMRON sales representative.
they apply at the total travel position.
Reed switch
100 VDC max.
0.25 A max.
10 W max.
0.1 mm to 1 m/s (pin plunger models)
Mechanical:
Electrical:
100 MΩ min. (at 500 VDC)
150 mΩ max.
200 VDC for 1 min between terminals of same polarity
500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each
terminal and non-current-carrying metal part
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction:500 m/s
Malfunction:200 m/s
Mechanical:
Electrical:
IEC IP40
Class I
175
–10°C to 60°C (at ambient humidity of 60% max.) (with no icing or condensation)
80% max. (for 5°C to 35°C)
Approx. 7 g (pin plunger models with terminals)
10,000,000 operations min. (200 operations/min)
3,000,000 operations min. (200 operaions/min)
200 operations/min max.
200 operations/min max.
2
2
{approx. 50G} max.
{approx. 20G} max.
Note:
The values apply under the following test conditions:
Ambient temperature: 20±2°C
Ambient humidity: 65±5%
Operating frequency: 30 operations/min
D2RV