Specifications of ASDX015A24R-DO

Operating Pressure
0 psi to 15 psi
Pressure Type
Gauge, Differential, Absolute
Output Type
Amplified
Mounting Style
Through Hole
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 20 C
Operating Supply Voltage
4.75 V to 6.5 V
Package / Case
DIP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ASDX015A24R-DO
Manufacturer:
HONEYWELL
Quantity:
20 000
Installation Instructions for the
ASDX DO Series Pressure Sensors
GENERAL INFORMATION
The ASDX DO series pressure sensors are fully
calibrated and temperature compensated with on-
board Application Specific Integrated Circuitry (ASIC).
This ASDX DO device is in a standard DIP package
and provides digital correction of sensor offset,
sensitivity, temperature coefficients and non-linearity.
The ASDX family uses I
which allows easy interfacing to most commonly
used microcontrollers and microprocessors without
additional components or electronic circuitry.
The 2-wire I
(SCL) input and serial digital output data line. The
output of the device is a corrected pressure value in
hexadecimal format with 12-bit accuracy. Devices
are available to measure absolute, differential, and
gage pressures. The absolute devices have an
internal vacuum reference and an output proportional
to absolute pressure. Differential devices allow
application of pressure to either side of the sensing
diaphragm and can be used for gage or differential
measurements.
ELECTRICAL CONNECTIONS
Note 1:
Note 2:
Note 3:
Note 4:
Sensing and Control
PERSONAL INJURY
DO NOT USE these products as safety or
emergency stop devices or in any other application
where failure of the product could result in personal
injury.
Failure to comply with these instructions could
result in death or serious injury.
WARNING
Pin 6 must be left open
Capacitor 220 nF required between +Vs and GND, and 15 nF between Vout and GND.
The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin can cause
electrical failure. Application of supply voltage above the maximum can cause electrical failure.
N/C means no connection, connecting to ground or other potential may damage sensor.
ASDXXXXD4DO
2
C interface has a Serial Clock Line
2
C compatible protocol,
(1)(2)(3)(4)
ASDXXXXG2DO
All ASDX DO devices are accurate to within ± 2.0 %
full scale. The devices are characterized for
operation from a single 5 Vdc supply. The sensor is
designed and manufactured according to standards
laid down in ISO 9001. These devices are intended
for use with non-corrosive, non-ionic working fluids
such as air and dry gases.
SPECIFICATIONS
Supply Voltage (Vs)*
Maximum Supply Voltage*
Consumption Current
*Note: The sensor is not reverse polarity protected. Incorrect
ENVIRONMENTAL SPECIFICATIONS (all devices)
Temperature Ranges:
Vibration:
Shock:
Life:
SOLDERING
Limit soldering to 250 °C [482 °F] maximum, with
duration of 2 seconds to 4 seconds.
CLEANING
Proper cleaning fluids should be selected, based on
the type of contaminants to be removed. Honeywell
recommends alcohols or fluorinated solvents. Do not
immerse the sensor.
Compensated:
Operating:
Storage:
application of excitation voltage or ground to the wrong pin
can cause electrical failure. Application of supply voltage
above the maximum can cause electrical failure.
0 °C to 85 °C [32 °F to 185 °F]
-20 °C to 105 °C [-4 °F to 221 °F]
-40 °C to125 °C [-40 °F to 257 °F]
10 g at 20 Hz to 2000 Hz
50 g for 11 ms
1 million cycles minimum
4.75 Vdc to 5.25 Vdc
6.50 Vdc (max.)
6 mA (typ)
ASDXXXXA2DO
50005537
ISSUE 1

Related parts for ASDX015A24R-DO

ASDX015A24R-DO Summary of contents

Page 1

... SOLDERING Limit soldering to 250 °C [482 °F] maximum, with duration of 2 seconds to 4 seconds. CLEANING Proper cleaning fluids should be selected, based on the type of contaminants to be removed. Honeywell recommends alcohols or fluorinated solvents. Do not immerse the sensor. ASDXXXXG2DO ISSUE 1 50005537 4 ...

Page 2

... Copyright 2004 Honeywell International Inc. All Rights Reserved. Issue 1 G2 PACKAGE While we provide application assistance personally, through our literature and the Honeywell web site the customer to determine the suitability of the product in the application. For application assistance, current specifications, or name of the nearest Authorized Distributor, contact a nearby sales office. Or ...