E32-VF1 Omron, E32-VF1 Datasheet

no-image

E32-VF1

Manufacturer Part Number
E32-VF1
Description
Fiber Optic Sensors 1 CHANNEL VACUUM FLANGE
Manufacturer
Omron
Datasheets

Specifications of E32-VF1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Omron’s First Complete System for
Sensing Under Vacuum
H
H
H
H
H
H
H
Ordering Information
J CONFIGURATION EXAMPLE (TYPICAL)
To Order a Complete Fiber-Optic System for Sensing Under Vacuum
Select:
D A Flange
D Vacuum Fibers
D External Fiber Cable
D A Lens Unit (if necessary)
D The Appropriate Fiber-Optic Amplifier
J FLANGES
J VACUUM FIBERS
Item
Four channel
One-channel
Item
Part number
Fiber-Optic System for Sensing Under Vacuum
Vacuum rated to 1 x 10
max. (7.5 x 10
The industry’s First 4-Channel Snap-On
Fiber Mounting Feature allows ease of
use and implementation
A Single-Channel Flange with
screw-mounting is also available
Increases process productivity by
performing operations inside vacuum
chambers
The external fiber can be cut on both
ends, allowing customized lengths
Stainless steel and fluoro-resin fiber
cables are available for vacuum
processes
CE approval
Through-beam, straight model
E32-T51V 1M
E32-T51V 0.5M
-10
torr S l/s)
R
- -10
Pa S m
E39-F1V
Lens Unit
3
/s
Through-beam, 90° model
E32-T54V 1M
E32-T54V 0.5M
Vacuum chamber
A combination of
E32-T51V, E32-T54V, and
E32-T84SV Vacuum Fibers E32-VF4 Four-Channel Flange or
Inside vacuum
chamber
E32-VF1 One-Channel Flange
Outside
Part number
E32-VF4
E32-VF1
Through-beam, heat-resistant model
E32-T84SV 1M
- - - -
A pair of E32-T10V
Fibers for outside
E3X-NMVV or
E3X-NH11
Amplifier Unit
E32-V

Related parts for E32-VF1

E32-VF1 Summary of contents

Page 1

... E32-T51V 0. Vacuum chamber Inside vacuum E39-F1V chamber Lens Unit A combination of E32-T51V, E32-T54V, and E32-T84SV Vacuum Fibers E32-VF4 Four-Channel Flange or E32-VF1 One-Channel Flange Through-beam, 90° model E32-T54V 1M E32-T54V 0.5M E32-V Outside A pair of E32-T10V Fibers for outside E3X-NMVV or E3X-NH11 Amplifier Unit Part number ...

Page 2

... Pink and blue (0 V) wires are not short-circuited when remote input is OFF. (Open min.; max. input voltage Response time is 0.5 ms max. when remote input is OFF. Light-ON and Dark-ON switch-selectable E32-V Part number E32-T10V 2M Part number E39-F1V PNP output E3X-NH41 ...

Page 3

... PNP open collector NPN open collector Load current: Load current max max. Residual voltage: Residual voltage max max. Load VDC, 10 kΩ min. Load resistance 10 kΩ min. E32-V PNP output E3X-DAN51 PNP open collector Load current max. Residual voltage max. 3 ...

Page 4

... Fluoro-resin Aluminum (A5056), Stainless steel (SS 304) E39-F1V E32-T51V 360 mm 700 25°C to 120° 13°F to 248°F) with no icing Aluminum (A5056) Optical glass E32-V E32-VF1 One-channel Stainless steel (SS 304) Approx. 220 g E32-T84SV 150 mm 400 25°C to 200° max. Optical glass Optical glass ...

Page 5

... E32-V Dimensions Unit: mm (inch) J FLANGES E32-VF4 E32-VF1 49 (1.93) 36 (1.42) dia (0.94) Flange (vacuum side) Flange (outside) O ring Mounting hole: 38 ±0.5 (1.50 ±0.02) dia. 23 (0.90) 22 (0.87) 22 (0.87) Two, Nut M14 Connector Washer O ring Mounting hole: 14.5±0.2 (0.57 ±0.01) dia. E32-V 44 (1.73) dia. ...

Page 6

... Material: SS 304 23 (0.90) 15 (0.59) 0.5 4.1 (0.02) (0.16) E32-V 4 (0.16) dia. 2.2 (0.09) dia. Connects to Flange (vacuum side). 26 (1.02) 2.2 (0.09) 4 (0.16) dia. dia. 26 (1.02) Connects to Flange (vacuum side). 2.2-(0.09) dia. 4 (0.16) sleeve dia ...

Page 7

... Two, 3.2- (0.13) dia. holes 3.4 (0.13) 44 (1.73) 16 (0.63) 22.4 (0.88) E32-V * Note: The mounting bracket can be at- tached to side A. (Side see note) 7 (0.28) Incident level indicators 6 (0.24) 32.5 (1.28) 2.4 (0.09 ...

Page 8

... Two, 3.2-dia. holes (0.33) Two, mounting holes 22.4 (0.88) E32-V Note: The mounting bracket Stability indicator can be attached to this side. 10 (0.39) 3.5 6.2 (0.14) (0.24) 59 (2.32) 32.5 (1.28) 3.8 (0.15) 16 (0.63) 6 ...

Page 9

... Two, 3.2-mm-dia. holes Mounting bracket SUS304 stainless steel 4.4 3.4 Two, mounting holes 22.4 16 E32-V The mounting bracket can be attached to this side. 8 Mounting Holes 3.3 (0.13) Two 32.5 (1.28) 10.75 2 mm-dia. vinyl-insulated round cable with 3/4 conduc- tors (40/0 ...

Page 10

... Sensing distance (cm) J PARALLEL OPERATING RANGE (TYPICAL) E32-T51V E32-T51V E32-T51V with E39-F1V Sensing distance X (cm) E32-T84SV Sensing distance X (cm) 10 E32-T54V Sensing distance E32-T54V with E39-F1V E32-T54V Sensing distance (cm) E32-T54V E32-T54V E32-V E32-T84SV Sensing distance Sensing distance (cm) E32-T54V with E39-F1V Sensing distance X (cm) ...

Page 11

... Sensing Distance (mm 100 200 300 400 500 Sensing Distance (mm) E32-T54V 250 300 E32-T54V - - E39-F1V 1500 2000 200 400 0 600 700 E32-V 100 200 300 400 Sensing Distance (mm) 600 800 1000 1200 1400 1600 1800 2000 Sensing Distance (mm) 11 ...

Page 12

... E32-V J PARALLEL OPERATING RANGE (TYPICAL) E32-T51V E32-T51V + E39-F1V 150 100 Fiber Fiber with lens - - 100 - - 150 0 500 1000 Sensing Distance (mm) E32-T54V E32-T54V + E39-F1V 100 80 Fiber Fiber with lens - - 100 1000 0 500 Sensing Distance (mm) E32-T84SV 500 1000 Sensing Distance (mm) 12 1500 2000 ...

Page 13

... E32-V Precautions J APPLICATIONS The E32-V Vacuum Fiber Unit is used to detect a variety of objects located in high-vacuum chambers heated up to 120°C (some chambers operate at a maximum temperature of 200°C). J CLEANING Although Flanges, Vacuum Fibers, and Lens Units are cleaned before shipping, clean them with alcohol before use in high-vacuum chambers to make sure there is no foreign matter on them ...

Page 14

... OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. CEDSAX4 11/01 OMRON ON- -LINE Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci Specifications subject to change without notice. E32-V OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in U.S.A. ...