TL-Q5MC15 5M Omron, TL-Q5MC15 5M Datasheet - Page 4

no-image

TL-Q5MC15 5M

Manufacturer Part Number
TL-Q5MC15 5M
Description
Proximity Sensors RECT PRX 5MM NPN NO ALT FRQ
Manufacturer
Omron
Series
TL-Qr
Datasheet

Specifications of TL-Q5MC15 5M

Sensing Distance
0.197" (5mm)
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
500Hz
Material - Body
ABS Resin
Shielding
Unshielded
Voltage - Supply
10 V ~ 30 V
Output Type
NPN-NO
Terminal Type
2-Wire
Package / Case
Box
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
*2. E Models (DC switching models): A full-wave rectification power supply of 24 VDC ±10% (average value) can be used.
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard
sensing object
Response
frequency *1
Power supply
voltage *2
(operating voltage
range)
Current
consumption
Leakage current
Control
output
Indicators
Operation mode
(with sensing ob-
ject approaching)
Protection circuits
Ambient
temperature range
Ambient
humidity range
Temperature
influence
Voltage influence
Insulation
resistance
Dielectric strength
Vibration
resistance
Shock resistance
Degree of
protection
Connection
method
Weight
(packed state)
Materi-
als
Accessories
a set distance of half the sensing distance.
Load
current
Residual
voltage
Case
Sensing
surface
Model
5 mm ±10%
0 to 4 mm
15% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 6 and 7.)
Iron, 30 × 30 × 1 mm
E Models: 500 Hz
Y Models: 10 Hz
E Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
E Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC
Y Models: Refer to Engineering Data on page 5.
E Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC
Y Models: 10 to 200 mA
E Models: 1 V max. (load current: 200 mA)
Y Models: Refer to Engineering Data on page 5.
E Models: Detection indicator (red)
Y Models: Operation indicator (red)
E1/Y1 Models: NO
E2/Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
E Models: Reverse polarity protection, Surge suppressor
Y Models: Surge suppressor
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
E Models: ±2.5% max. of sensing distance at rated voltage in rated voltage ±10% range
Y Models: ±1% max. of sensing distance at rated voltage in rated voltage ±10% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
E Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models (Standard cable length: 2 m)
Approx. 145 g
Heat-resistant ABS
E Models: Mounting Bracket, Instruction manual
Y Models: Instruction manual
TL-N5ME@, TL-N5MY@
2
10 times each in X, Y, and Z directions
0 to 8 mm
Iron, 40 × 40 × 1 mm
Approx. 170 g
10 mm ±10%
TL-N10ME@, TL-N10MY@
20 mm ±10%
0 to 16 mm
Iron, 50 × 50 × 1 mm
E Models: 40 Hz
Y Models: 10 Hz
Approx. 240 g
TL-N/TL-Q/TL-G
TL-N20ME@, TL-N20MY@
4

Related parts for TL-Q5MC15 5M