Specifications of E2CY-C2A

Maximum Operating Temperature
+ 55 C
Operating Supply Voltage
10 V to 30 V
Sensing Distance
2 mm
Minimum Operating Temperature
- 10 C
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
-
Material - Body
Stainless Steel
Shielding
Shielded
Voltage - Supply
-
Output Type
-
Terminal Type
3-Wire
Package / Case
Cylinder
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
E2CY
Specifications Table
Note: When extending the cable, use a 1.5D-2V (equivalent to JIS C 3501) cable with characteristic impedance of 50 Ω.
Amplifier Unit
2
Part number
Ambient humidity
Vibration resistance
Shock resistance
Enclosure rating
Connecting cable length
Compensation range of cable length characteristic
Material
Weight (packaged state)
Accessories
Supply voltage
Current consumption
Sensing distance adjustment range
Adjustment method
Differential travel
Response time
Control output
Self-diagnostic output
Circuit protection
Cable length
Cable length compensation
Indicators
Ambient temperature
Ambient humidity
Influence of temperature on sensing distance
(at 23°C)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Material
Teaching monitor function
Output status
Weight (packaged state)
Accessories
- - continued from previous page
Operating
Case
Sensing surface
Cable
Operating
Operating
Case
Cover
12 to 24 VDC ± 10%, ripple (p-p): ±10% max.
40 mA max.
10% min. of stable sensing distance
Teaching
10% max. of sensing distance in FINE mode.
15% max. of sensing distance in NORM mode.
Refer to the response frequency of the Sensor Head in use.
NPN open collector output of 100 mA max. with a max. residual voltage of 1 V
NPN open collector output of 100 mA max. with a max. residual voltage of 1 V
Reverse polarity, surge voltage, and load short-circuit (for both control output and
diagnosis output)
2 m, pull-out cable
Freely cut or extended within a range between 0.5 and 5 m
Operation indicator (orange)
Excess gain level indicators (ON in green with sensing object in proximity and
ON in orange with no sensing object in proximity)
Fine-tuning indicator (green)
- -10°C to 55°C (14°F to 131°F) with no icing
35 to 85%
±10% max. - -10°C to 55°C (14°F to 131°F)
50 MΩ min. (at 500 VDC) between current carrying parts and case
1,000 VAC (50/60 Hz) for 1 min between current carrying parts and case
Destruction: 10 to 150 Hz, 1.5-mm double amplitude or 100 m/s
for 2 hours each in X, Y, and Z directions
Destruction: 300 m/s
IEC IP50 with the sensor cable and protective cover attached
PTB resin
Polycarbonate
Orange and green indicators shared by operation and excess gain indication
Normally open or normally closed selectable
Approx. 75 g (with 2-m cable)
Mounting brackets and instruction sheet
E2CY-X1R5A
35% to 95%
Destruction: 10 to 500 Hz, 2.0-mm double amplitude or 150 m/s
for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
IEC IP67
Coaxial cable with a standard length of 3 m for high-frequency use
0.5 to 5 m (See Note.)
Stainless steel
Heat-resistant ABS resin
Soft vinyl chloride
Approx. 35 g (with 3 m cord)
M5 nut with toothed
washer
2
2
(approx. 30G) for 3 hours each in X, Y, and Z directions
(approx. 50G) three times each in X, Y, Z directions
E2CY-C2A
---
E2CY-V3A
Zinc die-cast
M2 screw, hexagonal nut,
spring washer, and flat
washer
2
2
(approx. 10G)
(approx. 15G)
E2CY