CS4299-BQZ Cirrus Logic Inc, CS4299-BQZ Datasheet - Page 46

no-image

CS4299-BQZ

Manufacturer Part Number
CS4299-BQZ
Description
IC CODEC AC'97 W/SRC 48-LQFP
Manufacturer
Cirrus Logic Inc
Series
SoundFusion™r
Type
Audio Codec '97r
Datasheet

Specifications of CS4299-BQZ

Data Interface
Serial
Resolution (bits)
18 b, 20 b
Number Of Adcs / Dacs
1 / 1
Sigma Delta
Yes
Voltage - Supply, Analog
4.75 V ~ 5.25 V
Voltage - Supply, Digital
3.3 V ~ 5 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
48-LQFP
Audio Codec Type
Stereo
No. Of Adcs
1
No. Of Dacs
1
No. Of Input Channels
8
No. Of Output Channels
3
Adc / Dac Resolution
20bit
Sampling Rate
48kSPS
Ic Interface Type
Serial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS4299-BQZ
Manufacturer:
CirrusLogic
Quantity:
3 712
Part Number:
CS4299-BQZ
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS4299-BQZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS4299-BQZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
AC-Link
RESET# - AC ’97 Chip Reset, Input, Pin 11
SYNC - AC-Link Serial Port Sync pulse, Input, Pin 10
BIT_CLK - AC-Link Serial Port Master Clock, Input/Output, Pin 6
SDATA_OUT - AC-Link Serial Data Input Stream to AC ’97, Input, Pin 5
SDATA_IN - AC-Link Serial Data Output Stream from AC ’97, Output, Pin 8
Power Supplies
DVdd1, DVdd2 - Digital Supply Voltage, Pins 1 and 9
DVss1, DVss2 - Digital Ground, Pins 4 and 7
AVdd1, AVdd2 - Analog Supply Voltage, Pins 25 and 38
AVss1, AVss2 - Analog Ground, Pins 26 and 42
46
46
This active low signal is the asynchronous Cold Reset input to the CS4299. The CS4299 must be reset
before it can enter normal operating mode.
This signal is the serial port timing signal for the AC-link. Its period is the reciprocal of the maximum
sample rate, 48 kHz. The signal is generated by the controller, synchronous to BIT_CLK. SYNC is an
asynchronous input when the CS4299 is configured as a primary audio codec and is in a PR4
powerdown state. A series terminating resistor of 47 Ω should be connected on the signal near the
SYNC source.
This input/output signal controls the master clock timing for the AC-link. In primary mode, this signal is a
12.288 MHz output clock derived from a 24.576 MHz crystal on the XTL_IN input clock. When the
CS4299 is in secondary mode, this signal is an input which controls the AC-link serial interface and
generates all internal clocking including the AC-link serial interface timing and the analog sampling
clocks. A series terminating resistor of 47 Ω should be connected on this signal close to the CS4299 in
primary mode or close to the BIT_CLK source in secondary mode.
This input signal receives the control information and digital audio output streams. The data is clocked
into the CS4299 on the falling edge of BIT_CLK. A series terminating resistor of 47 Ω should be
connected on this signal near the controller.
This output signal transmits the status information and digital audio input streams from the ADCs. The
data is clocked out of the CS4299 on the rising edge of BIT_CLK. A series terminating resistor of 47 Ω
should be connected on this signal as close to the CS4299 as possible.
Digital supply voltage for the AC-link section of the CS4299. These pins can be tied to +5 V digital or to
+3.3 V digital. The CS4299 and controller AC-link should share a common digital supply
Digital ground connection for the AC-link section of the CS4299. These pins should be isolated from
analog ground currents.
Analog supply voltage for the analog and mixed signal sections of the CS4299. These pins must be tied
to the analog +5 V power supply. It is strongly recommended that +5 V be generated from a voltage
regulator to ensure proper supply currents and noise immunity from the rest of the system.
Ground connection for the analog, mixed signal, and substrate sections of the CS4299. These pins
should be isolated from digital ground currents.
CS4299
CS4299
DS319PP6

Related parts for CS4299-BQZ