PB-120N-13C Mean Well, PB-120N-13C Datasheet

Battery Chargers 99.36W 13.8V 7.2A V DETECTOR W/O PFC

PB-120N-13C

Manufacturer Part Number
PB-120N-13C
Description
Battery Chargers 99.36W 13.8V 7.2A V DETECTOR W/O PFC
Manufacturer
Mean Well
Datasheet

Specifications of PB-120N-13C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
SPECIFICATION
MODEL
OUTPUT
INPUT
PROTECTION
ENVIRONMENT
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
S:Power Supply
A:Voltage detector
B:Current detector
P:With PFC
N:None PFC
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
LED INDICATED
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
DIMENSION
PACKING
120W Single Output Power Supply or Battery Charger
P A
120 P
RTH2 70
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
13.8V
7.2A
0 ~ 7.2A
99.36W
PA series voltage 105% 1% : RED / 105% 1% :GREEN
PB series load 46% 10% : GREEN / 46% 10% :RED
88 ~ 132VAC / 176 ~ 264VAC selected by switch
47 ~ 63Hz
>0.65 (with PFC series)
3A/115VAC
PA/PB-120 -13
73%
COLD START 25A/115VAC
<1.5mA / 240VAC
90 ~ 110% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
15 ~ 17V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-10 ~ +45
20 ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, EN60335, EN60335-1, EN60335-2-29 approved
I/P-O/P:3KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
149.6K hrs min.
PCB Type:144*90*33mm
1.1Kg; 16pcs / 17.9Kg / 1.47CUFT(without PFC)
0.05%/
(0 ~ 45
(Refer to output load derating curve)
13 C
10
1.5A/230VAC
I/P-FG:1.5KVAC
MIL-HDBK-217F (25 )
detect on RTH2 thermistor
P:Open P.C.B.
C:With case
13:13.8V
27:27.6V
54:55.2V
External case type:180*96*49mm (L*W*H)
50A/230VAC
:O.D.M. number
O/P-FG:0.5KVAC
4.3A
27.6V
0 ~ 4.3A
118.68W
30 ~ 35V
PA/PB-120 -27
79%
1.24Kg; 16pcs / 20.1Kg / 1.47CUFT(with PFC)
248 ~ 370VDC
PA / P B - 1 2 0
2.2A
55.2V
0 ~ 2.2A
121.44W
60 ~ 66V
PA/PB-120 -54
79%
File Name:PA,PB-120-SPEC 2008-11-11
TUV
Rheinland
Product Safety
Sicherheit
geprUfre
s e r i e s

Related parts for PB-120N-13C

PB-120N-13C Summary of contents

Page 1

... CURRENT RANGE 0 ~ 7.2A OUTPUT RATED POWER 99.36W PA series voltage 105 RED / 105% 1% :GREEN LED INDICATED PB series load 46% 10% : GREEN / 46% 10% :RED VOLTAGE RANGE 88 ~ 132VAC / 176 ~ 264VAC selected by switch FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) >0.65 (with PFC series) INPUT EFFICIENCY (Typ.) ...

Page 2

... CN4 LED CN5 SHORT FOR 115V OPEN FOR 230V Vout Iout Bat. Voltage Charging Current 100% 45% T Red Green Type A:Voltage detecter,pulse charger Vout Iout Bat. Voltage Charging Current 100% T Red Green Type B:Current detecter,2 voltage section File Name:PA,PB-120-SPEC 2008-11- Unit: ...