YNV12T16-0 POWER ONE, YNV12T16-0 Datasheet - Page 7

DC/DC Converters & Regulators

YNV12T16-0

Manufacturer Part Number
YNV12T16-0
Description
DC/DC Converters & Regulators
Manufacturer
POWER ONE
Datasheet

Specifications of YNV12T16-0

Product
Non-Isolated / POL
Output Power
88 W
Input Voltage Range
9.6 V to 14 V
Input Voltage (nominal)
12 V
Number Of Outputs
1
Output Current (channel 1)
16 A
Package / Case Size
SIP
Output Type
Regulated
Output Voltage
0.7525 V to 5.5 V
Package / Case
SIP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
the voltage source; the value can be chosen
depending on the required output voltage range
[k]
Control voltages with
are shown in Table 2.
ZD-02039 Rev. 3.2, 24-Jun-10
R
V
EXT
0-REG
0.7525
1.0
1.2
1.5
1.8
2.0
2.5
3.3
5.0
5.5
External resistor between the TRIM pin and
[V]
Table 2: Control Voltage [VDC]
V
CTRL
0.700
0.684
0.670
0.650
0.630
0.617
0.584
0.530
0.417
0.384
(R
EXT
R
= 0)
EXT
9.6-14 VDC Input; 0.7525-5.5 VDC Programmable @ 16A
0 and
V
CTRL
(R
-0.097
-0.417
-0.631
-1.164
-2.017
-3.831
-4.364
0.700
0.436
0.223
EXT
R
EXT
= 15kΩ)
15 kΩ
YNV12T16 DC-DC Converter Data Sheet
Page 7 of 28
Protection Features
Input Undervoltage Lockout
Input undervoltage lockout is standard with this
converter. The converter will shut down when the
input voltage drops below a pre-determined
voltage; it will start automatically when Vin returns
to a specified range.
The input voltage must be at least 9.6 V (typically
9 V) for the converter to turn on. Once the
converter has been turned on, it will shut off when
the input voltage drops below typically 8.5 V.
Output Overcurrent Protection (OCP)
The converter is protected against overcurrent and
short-circuit
overcurrent condition, the converter will enter
hiccup mode. Once the overload or short-circuit
condition is removed, Vout will return to nominal
value.
Overtemperature Protection (OTP)
The
overtemperature condition to protect itself from
overheating caused by operation outside the
thermal derating curves, or operation in abnormal
conditions such as system fan failure. After the
converter
temperature, it will automatically restart.
Safety Requirements
The
International safety regulatory requirements per
UL60950 and EN60950. The maximum DC
voltage between any two pins is Vin under all
operating conditions. Therefore, the unit has ELV
(extra low voltage) output; it meets SELV
requirements under the condition that all input
voltages are ELV.
The converter is not internally fused. To comply
with safety agencies requirements, a recognized
fuse with a maximum rating of 15 Amps must be
used in series with the input line.
converter
converter
has cooled to
www.power-one.com
conditions.
meets
will
shut
North
Upon
a safe operating
down
American
sensing
under
and
an
an

Related parts for YNV12T16-0